WEKO3
アイテム
{"_buckets": {"deposit": "da17bf51-1894-42e2-a40b-dc2310508eaa"}, "_deposit": {"created_by": 1, "id": "46594", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46594"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046594", "sets": ["1"]}, "author_link": ["464451", "464457", "464455", "464454", "464452", "464453", "464456"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-07", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{"bibliographic_title": "International Journal of Computer Assisted Radiology and Surgery"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: Modeling the postmortem liver for autopsy imaging is a challenging problem owing to the variation in organ deformation found in cadavers and limited availability of postmortem liver CT scans. An algorithm was developed to construct a statistical shape model (SSM) for the adult postmortem liver in autopsy imaging.\n\\nMethods: First, we investigated the relationship between SSMs obtained from in vivo liver CT scans and those from postmortem cases. Liver shapes were embedded in level set functions and statistically modeled using a spatially weighted principal components analysis. The performance of the SSMs was evaluated in terms of generalization and specificity. Several algorithms for the transformation from in vivo livers to postmortem livers were proposed to enhance the performance of an SSM for a postmortem liver, followed by a comparative study on SSMs. Specifically, five SSMs for a postmortem liver were constructed and evaluated using 32 postmortem liver labels, and postmortem liver labels synthesized from 144 in vivo liver labels were constructed using the proposed transformation algorithms. We also compared the proposed SSMs with three conventional SSMs trained from postmortem liver labels and/or in vivo liver labels.\n\\nResults: The investigation showed that the performance of an SSM constructed using in vivo liver labels suffered when describing postmortem liver shapes. Two of the five proposed SSMs trained using synthesized postmortem livers showed the best performance with no significant differences between them, and they statistically outperformed all conventional SSMs tested.\n\\nConclusions: The performance of conventional SSMs can be improved by using both postmortem liver shape labels and artificial shape labels synthesized from in vivo liver shape labels.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s11548-013-0923-6", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://link.springer.com/article/10.1007/s11548-013-0923-6"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://link.springer.com/article/10.1007/s11548-013-0923-6", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1861-6410", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Saito, Atsushi"}], "nameIdentifiers": [{"nameIdentifier": "464451", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shimizu, Akinobu"}], "nameIdentifiers": [{"nameIdentifier": "464452", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Watanabe, Hidefumi"}], "nameIdentifiers": [{"nameIdentifier": "464453", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamamoto, Seiji"}], "nameIdentifiers": [{"nameIdentifier": "464454", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "464455", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "齋藤 篤", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "464456", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山本 正二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "464457", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Statistical shape model of a liver for autopsy imaging", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Statistical shape model of a liver for autopsy imaging"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46594", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-09-18"}, "publish_date": "2013-09-18", "publish_status": "0", "recid": "46594", "relation": {}, "relation_version_is_last": true, "title": ["Statistical shape model of a liver for autopsy imaging"], "weko_shared_id": -1}
Statistical shape model of a liver for autopsy imaging
https://repo.qst.go.jp/records/46594
https://repo.qst.go.jp/records/46594e6997566-ab97-4c50-999c-1d0eed854325
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-09-18 | |||||
タイトル | ||||||
タイトル | Statistical shape model of a liver for autopsy imaging | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Saito, Atsushi
× Saito, Atsushi× Shimizu, Akinobu× Watanabe, Hidefumi× Yamamoto, Seiji× et.al× 齋藤 篤× 山本 正二 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: Modeling the postmortem liver for autopsy imaging is a challenging problem owing to the variation in organ deformation found in cadavers and limited availability of postmortem liver CT scans. An algorithm was developed to construct a statistical shape model (SSM) for the adult postmortem liver in autopsy imaging. \nMethods: First, we investigated the relationship between SSMs obtained from in vivo liver CT scans and those from postmortem cases. Liver shapes were embedded in level set functions and statistically modeled using a spatially weighted principal components analysis. The performance of the SSMs was evaluated in terms of generalization and specificity. Several algorithms for the transformation from in vivo livers to postmortem livers were proposed to enhance the performance of an SSM for a postmortem liver, followed by a comparative study on SSMs. Specifically, five SSMs for a postmortem liver were constructed and evaluated using 32 postmortem liver labels, and postmortem liver labels synthesized from 144 in vivo liver labels were constructed using the proposed transformation algorithms. We also compared the proposed SSMs with three conventional SSMs trained from postmortem liver labels and/or in vivo liver labels. \nResults: The investigation showed that the performance of an SSM constructed using in vivo liver labels suffered when describing postmortem liver shapes. Two of the five proposed SSMs trained using synthesized postmortem livers showed the best performance with no significant differences between them, and they statistically outperformed all conventional SSMs tested. \nConclusions: The performance of conventional SSMs can be improved by using both postmortem liver shape labels and artificial shape labels synthesized from in vivo liver shape labels. |
|||||
書誌情報 |
International Journal of Computer Assisted Radiology and Surgery 発行日 2013-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1861-6410 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s11548-013-0923-6 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://link.springer.com/article/10.1007/s11548-013-0923-6 | |||||
関連名称 | http://link.springer.com/article/10.1007/s11548-013-0923-6 |