{"_buckets": {"deposit": "d1d62842-eda2-466d-8904-449a71c2de4f"}, "_deposit": {"created_by": 1, "id": "46542", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46542"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046542", "sets": ["1"]}, "author_link": ["463841", "463840", "463839", "463843", "463838", "463837", "463842"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-06", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "28", "bibliographicPageStart": "22", "bibliographicVolumeNumber": "689", "bibliographic_titles": [{"bibliographic_title": "Nuclear Instruments \u0026 Methods in Physics Research Section A"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We developed a real-time and non-destructive method of beam profile measurement on a target under large beam current irradiation, and without any complex radiation detectors or electrical circuits. We measured the beam profiles on a target by observing the target temperature using an infrared-radiation thermometer camera. The target temperatures were increased and decreased quickly by starting and stopping the beam irradiation within 1 s in response speed. \n Our method could trace beam movements rapidly. The beam size and positiun were calibrated by measuring O-ring heat on the target. Our method has the potential to measure beam profiles at beam current over 1 mA for proton and deuteron with the energy around 3Mev and allows accelerator operators to adjust the beam location during beam irradiation experiments without decreaseing the beam current.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "org/10.1016/j.nima.2012.06.019", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0168-9002", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Takada, Masashi"}], "nameIdentifiers": [{"nameIdentifier": "463837", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kamada, So"}], "nameIdentifiers": [{"nameIdentifier": "463838", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hamano, Tsuyoshi"}], "nameIdentifiers": [{"nameIdentifier": "463839", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "463840", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高田 真志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "463841", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鎌田 創", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "463842", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱野 毅", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "463843", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Innovative real-time and non-destructive method of beam profile measurement under large beam current irradiation for BNCT", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Innovative real-time and non-destructive method of beam profile measurement under large beam current irradiation for BNCT"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46542", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-04-30"}, "publish_date": "2013-04-30", "publish_status": "0", "recid": "46542", "relation": {}, "relation_version_is_last": true, "title": ["Innovative real-time and non-destructive method of beam profile measurement under large beam current irradiation for BNCT"], "weko_shared_id": -1}
Innovative real-time and non-destructive method of beam profile measurement under large beam current irradiation for BNCT
https://repo.qst.go.jp/records/46542
https://repo.qst.go.jp/records/46542d648cfa6-d8bc-4f6c-8949-8c346a8b0a8a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-04-30 | |||||
タイトル | ||||||
タイトル | Innovative real-time and non-destructive method of beam profile measurement under large beam current irradiation for BNCT | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Takada, Masashi
× Takada, Masashi× Kamada, So× Hamano, Tsuyoshi× et.al× 高田 真志× 鎌田 創× 濱野 毅 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We developed a real-time and non-destructive method of beam profile measurement on a target under large beam current irradiation, and without any complex radiation detectors or electrical circuits. We measured the beam profiles on a target by observing the target temperature using an infrared-radiation thermometer camera. The target temperatures were increased and decreased quickly by starting and stopping the beam irradiation within 1 s in response speed. Our method could trace beam movements rapidly. The beam size and positiun were calibrated by measuring O-ring heat on the target. Our method has the potential to measure beam profiles at beam current over 1 mA for proton and deuteron with the energy around 3Mev and allows accelerator operators to adjust the beam location during beam irradiation experiments without decreaseing the beam current. |
|||||
書誌情報 |
Nuclear Instruments & Methods in Physics Research Section A 巻 689, p. 22-28, 発行日 2012-06 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-9002 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | org/10.1016/j.nima.2012.06.019 |