{"_buckets": {"deposit": "cac78634-fdfe-4cc3-b7c4-74fdf54fc2b5"}, "_deposit": {"created_by": 1, "id": "46372", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46372"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046372", "sets": ["1"]}, "author_link": ["461947", "461949", "461941", "461938", "461945", "461951", "461942", "461943", "461944", "461948", "461939", "461950", "461940", "461946"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "386", "bibliographicPageStart": "379", "bibliographicVolumeNumber": "16", "bibliographic_titles": [{"bibliographic_title": "International Journal of Clinical Oncology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Background\n\\nTo assess radiotherapy protocol compliance in a multi-institutional phase II study of concurrent chemoradiotherapy for patients with locally advanced cancer of the uterine cervix (JGOG1066).\nMethods\n\\nFor study protocol development, various radiotherapy parameters were examined and consensus was reached by Japanese radiation oncologists with cervical cancer treatment expertise. Quality assurance (QA) was also discussed and included in the protocol. A credentialing process was used to select institutions for participation in the study. Individual case reviews referring to 18 QA items were undertaken for each patient. Radiotherapy data were submitted to the Japanese Gynecologic Oncology Group (JGOG) data center and reviewed by the members of the radiotherapy committee. The QA evaluation was classed as per protocol, deviation, and violation.\nResults\n\\nIndividual case reviews were performed on 69 of 72 patients entered in the study. In 24 patients (35%), there were no deviations for any QA items. There were also no deviations seen for 5 of the 18 items in 69 patients evaluated. Deviations of 64 QA items were seen in 45 cases, and violations were seen in 4 cases (4 items). The most common deviation concerned appropriate application for the external beam radiotherapy (EBRT) boost to involved nodes or parametrium (32 cases). The 4 violations were identified in the QA items regarding high-dose rate intracavitary brachytherapy.\nConclusions\n\\nRadiotherapy protocol compliance was favorable except for the EBRT boost indications. The results of this study validate the quality of radiotherapy in JGOG1066, and indicate that the final analysis will provide meaningful results.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s10147-011-0196-4", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1341-9625", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Toita, Takafumi"}], "nameIdentifiers": [{"nameIdentifier": "461938", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kato, Shingo"}], "nameIdentifiers": [{"nameIdentifier": "461939", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishikura, Satoru"}], "nameIdentifiers": [{"nameIdentifier": "461940", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kodaira, Takeshi"}], "nameIdentifiers": [{"nameIdentifier": "461941", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uno, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "461942", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hatano, Kazuo"}], "nameIdentifiers": [{"nameIdentifier": "461943", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakurai, Hideyuki"}], "nameIdentifiers": [{"nameIdentifier": "461944", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Niibe, Yuzuru"}], "nameIdentifiers": [{"nameIdentifier": "461945", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kazumoto, Tomoko"}], "nameIdentifiers": [{"nameIdentifier": "461946", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "461947", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加藤 眞吾", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "461948", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古平 毅", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "461949", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宇野 隆", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "461950", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "幡野 和男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "461951", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Radiotherapy quality assurance of the Japanese Gynecologic Oncology Group study (JGOG1066): a cooperative phase II study of concurrent chemoradiotherapy for uterine cervical cancer", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Radiotherapy quality assurance of the Japanese Gynecologic Oncology Group study (JGOG1066): a cooperative phase II study of concurrent chemoradiotherapy for uterine cervical cancer"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46372", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-07-31"}, "publish_date": "2012-07-31", "publish_status": "0", "recid": "46372", "relation": {}, "relation_version_is_last": true, "title": ["Radiotherapy quality assurance of the Japanese Gynecologic Oncology Group study (JGOG1066): a cooperative phase II study of concurrent chemoradiotherapy for uterine cervical cancer"], "weko_shared_id": -1}
Radiotherapy quality assurance of the Japanese Gynecologic Oncology Group study (JGOG1066): a cooperative phase II study of concurrent chemoradiotherapy for uterine cervical cancer
https://repo.qst.go.jp/records/46372
https://repo.qst.go.jp/records/46372f3ea0ce8-f73a-4e62-8cf2-c58efc25502d
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-07-31 | |||||
タイトル | ||||||
タイトル | Radiotherapy quality assurance of the Japanese Gynecologic Oncology Group study (JGOG1066): a cooperative phase II study of concurrent chemoradiotherapy for uterine cervical cancer | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Toita, Takafumi
× Toita, Takafumi× Kato, Shingo× Ishikura, Satoru× Kodaira, Takeshi× Uno, Takashi× Hatano, Kazuo× Sakurai, Hideyuki× Niibe, Yuzuru× Kazumoto, Tomoko× et.al× 加藤 眞吾× 古平 毅× 宇野 隆× 幡野 和男 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Background \nTo assess radiotherapy protocol compliance in a multi-institutional phase II study of concurrent chemoradiotherapy for patients with locally advanced cancer of the uterine cervix (JGOG1066). Methods \nFor study protocol development, various radiotherapy parameters were examined and consensus was reached by Japanese radiation oncologists with cervical cancer treatment expertise. Quality assurance (QA) was also discussed and included in the protocol. A credentialing process was used to select institutions for participation in the study. Individual case reviews referring to 18 QA items were undertaken for each patient. Radiotherapy data were submitted to the Japanese Gynecologic Oncology Group (JGOG) data center and reviewed by the members of the radiotherapy committee. The QA evaluation was classed as per protocol, deviation, and violation. Results \nIndividual case reviews were performed on 69 of 72 patients entered in the study. In 24 patients (35%), there were no deviations for any QA items. There were also no deviations seen for 5 of the 18 items in 69 patients evaluated. Deviations of 64 QA items were seen in 45 cases, and violations were seen in 4 cases (4 items). The most common deviation concerned appropriate application for the external beam radiotherapy (EBRT) boost to involved nodes or parametrium (32 cases). The 4 violations were identified in the QA items regarding high-dose rate intracavitary brachytherapy. Conclusions \nRadiotherapy protocol compliance was favorable except for the EBRT boost indications. The results of this study validate the quality of radiotherapy in JGOG1066, and indicate that the final analysis will provide meaningful results. |
|||||
書誌情報 |
International Journal of Clinical Oncology 巻 16, 号 4, p. 379-386, 発行日 2011-02 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1341-9625 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s10147-011-0196-4 |