WEKO3
アイテム
{"_buckets": {"deposit": "db8de246-b7de-414f-bc63-aa48d655c38a"}, "_deposit": {"created_by": 1, "id": "46365", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46365"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046365", "sets": ["1"]}, "author_link": ["461858", "461856", "461857", "461859"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "9", "bibliographicPageEnd": "1948", "bibliographicPageStart": "1944", "bibliographicVolumeNumber": "70", "bibliographic_titles": [{"bibliographic_title": "Applied Radiation and Isotopes"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We analyzed the activities of 239Pu, 240Pu, 239+240Pu, 241Pu, the ratio of number of atoms (atom ratio) for 240Pu/239Pu, and the activity ratio of 241Pu/239+240Pu in seawater reference materials, IAEA-443 and IAEA-381, using a highly sensitive isotope dilution sector field inductively coupled plasma mass spectrometry method. With a mean chemical yield of 65 % determined with 242Pu as a tracer, we found that the experimentally established values in IAEA-443 for 239Pu, 240Pu, 241Pu and 239+240Pu activities are almost the same as those in IAEA-381. Regarding the 239+240Pu activity, we provided the most precise and accurate result among the twelve laboratories which participated in the interlaboratory comparison. In addition, for the 240Pu/239Pu atom ratio, our results for IAEA-381 (0.2315 +/- 0.0008) and IAEA-443 (0.2325 +/- 0.0008) are in good agreement with the IAEA information value (0.229 +/- 0.006), but have much smaller uncertainty. Since the new seawater reference material, IAEA-443, is commercially available, it can be used not only for method validation for seawater plutonium isotope ratio and activity analysis, but also for more general use as a plutonium isotope standard for mass discrimination correction for other environmental samples.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0969-8043", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Zheng, Jian"}], "nameIdentifiers": [{"nameIdentifier": "461856", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Masatoshi"}], "nameIdentifiers": [{"nameIdentifier": "461857", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鄭 建", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "461858", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 正俊", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "461859", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Determination of plutonium isotopes in seawater reference materials using isotope-dilution ICP-MS", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Determination of plutonium isotopes in seawater reference materials using isotope-dilution ICP-MS"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46365", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-07-20"}, "publish_date": "2012-07-20", "publish_status": "0", "recid": "46365", "relation": {}, "relation_version_is_last": true, "title": ["Determination of plutonium isotopes in seawater reference materials using isotope-dilution ICP-MS"], "weko_shared_id": -1}
Determination of plutonium isotopes in seawater reference materials using isotope-dilution ICP-MS
https://repo.qst.go.jp/records/46365
https://repo.qst.go.jp/records/463657a95970e-7e1d-4a5e-be3b-973c642e0a34
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-07-20 | |||||
タイトル | ||||||
タイトル | Determination of plutonium isotopes in seawater reference materials using isotope-dilution ICP-MS | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Zheng, Jian
× Zheng, Jian× Yamada, Masatoshi× 鄭 建× 山田 正俊 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We analyzed the activities of 239Pu, 240Pu, 239+240Pu, 241Pu, the ratio of number of atoms (atom ratio) for 240Pu/239Pu, and the activity ratio of 241Pu/239+240Pu in seawater reference materials, IAEA-443 and IAEA-381, using a highly sensitive isotope dilution sector field inductively coupled plasma mass spectrometry method. With a mean chemical yield of 65 % determined with 242Pu as a tracer, we found that the experimentally established values in IAEA-443 for 239Pu, 240Pu, 241Pu and 239+240Pu activities are almost the same as those in IAEA-381. Regarding the 239+240Pu activity, we provided the most precise and accurate result among the twelve laboratories which participated in the interlaboratory comparison. In addition, for the 240Pu/239Pu atom ratio, our results for IAEA-381 (0.2315 +/- 0.0008) and IAEA-443 (0.2325 +/- 0.0008) are in good agreement with the IAEA information value (0.229 +/- 0.006), but have much smaller uncertainty. Since the new seawater reference material, IAEA-443, is commercially available, it can be used not only for method validation for seawater plutonium isotope ratio and activity analysis, but also for more general use as a plutonium isotope standard for mass discrimination correction for other environmental samples. | |||||
書誌情報 |
Applied Radiation and Isotopes 巻 70, 号 9, p. 1944-1948, 発行日 2012-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0969-8043 |