WEKO3
アイテム
{"_buckets": {"deposit": "a1359714-cf45-43b4-b232-82d5ed106c59"}, "_deposit": {"created_by": 1, "id": "46307", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46307"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046307", "sets": ["1"]}, "author_link": ["461319", "461315", "461318", "461314", "461317", "461321", "461316", "461320"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "15", "bibliographicPageEnd": "4770", "bibliographicPageStart": "4749", "bibliographicVolumeNumber": "56", "bibliographic_titles": [{"bibliographic_title": "Physics in Medicine and Biology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Intensity modulated proton therapy (IMPT) offers the possibility of generating\nexcellent target coverage while sparing the neighbouring organs at risk.\nHowever, treatment plans optimized for IMPT may be very sensitive to range and setup uncertainties. We developed a method to deal with these uncertainties in the dose optimization. This method aims at two objectives: one for maintaining the dose coverage within the target, and the other for preventing undesired exposure to organs at risk. The former objective was achieved by the algorithm described in our previous paper to suppress the in-field dose gradient within the target. In this study, the latter objective was achieved by a novel algorithm in which we suppressed pencil beams with high risk to deliver undesired doses to organs at risk under conditions where range and setup uncertainties occur. We defined the risk index that quantifies the likelihood of each pencil beam delivering high doses to organs at risk, and introduced it into the objective function of dose optimizations.\nIn order to test the algorithm\u0027s performance, this method was applied to an\nRTOG benchmark phantom geometry and to a cervical chordoma case. These simulations demonstrated that our method provides IMPT plans that are more robust against range and setup errors compared to conventional IMPT plans. Compared to the conventional IMPT plan, the optimization time for the robust plan increased by a factor of only 3, from 4 to 11 min.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "/10.1088/0031-9155/56/15/008", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0031-9155", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Inaniwa, Taku"}], "nameIdentifiers": [{"nameIdentifier": "461314", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanematsu, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "461315", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furukawa, Takuji"}], "nameIdentifiers": [{"nameIdentifier": "461316", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hasegawa, Azusa"}], "nameIdentifiers": [{"nameIdentifier": "461317", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲庭 拓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "461318", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "兼松 伸幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "461319", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 卓司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "461320", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長谷川 安都佐", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "461321", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A robust algorithm of intensity modulated proton therapy for critical tissue sparing and target coverage", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A robust algorithm of intensity modulated proton therapy for critical tissue sparing and target coverage"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46307", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-04-20"}, "publish_date": "2012-04-20", "publish_status": "0", "recid": "46307", "relation": {}, "relation_version_is_last": true, "title": ["A robust algorithm of intensity modulated proton therapy for critical tissue sparing and target coverage"], "weko_shared_id": -1}
A robust algorithm of intensity modulated proton therapy for critical tissue sparing and target coverage
https://repo.qst.go.jp/records/46307
https://repo.qst.go.jp/records/463079a36ab65-61a3-460f-8b09-b24c4e94c508
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-04-20 | |||||
タイトル | ||||||
タイトル | A robust algorithm of intensity modulated proton therapy for critical tissue sparing and target coverage | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Inaniwa, Taku
× Inaniwa, Taku× Kanematsu, Nobuyuki× Furukawa, Takuji× Hasegawa, Azusa× 稲庭 拓× 兼松 伸幸× 古川 卓司× 長谷川 安都佐 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Intensity modulated proton therapy (IMPT) offers the possibility of generating excellent target coverage while sparing the neighbouring organs at risk. However, treatment plans optimized for IMPT may be very sensitive to range and setup uncertainties. We developed a method to deal with these uncertainties in the dose optimization. This method aims at two objectives: one for maintaining the dose coverage within the target, and the other for preventing undesired exposure to organs at risk. The former objective was achieved by the algorithm described in our previous paper to suppress the in-field dose gradient within the target. In this study, the latter objective was achieved by a novel algorithm in which we suppressed pencil beams with high risk to deliver undesired doses to organs at risk under conditions where range and setup uncertainties occur. We defined the risk index that quantifies the likelihood of each pencil beam delivering high doses to organs at risk, and introduced it into the objective function of dose optimizations. In order to test the algorithm's performance, this method was applied to an RTOG benchmark phantom geometry and to a cervical chordoma case. These simulations demonstrated that our method provides IMPT plans that are more robust against range and setup errors compared to conventional IMPT plans. Compared to the conventional IMPT plan, the optimization time for the robust plan increased by a factor of only 3, from 4 to 11 min. |
|||||
書誌情報 |
Physics in Medicine and Biology 巻 56, 号 15, p. 4749-4770, 発行日 2011-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0031-9155 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | /10.1088/0031-9155/56/15/008 |