ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Relation between Lineal Energy Distribution and Relative Biological Effectiveness for Photon Beams according to the Microdosimetric Kinetic Model

https://repo.qst.go.jp/records/46105
https://repo.qst.go.jp/records/46105
ebd32da8-08a3-4e6b-b105-1476c6506be1
Item type 学術雑誌論文 / Journal Article(1)
公開日 2011-06-09
タイトル
タイトル Relation between Lineal Energy Distribution and Relative Biological Effectiveness for Photon Beams according to the Microdosimetric Kinetic Model
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Okamoto, Hiroki

× Okamoto, Hiroki

WEKO 458989

Okamoto, Hiroki

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 458990

Kanai, Tatsuaki

Search repository
Kase, Yuki

× Kase, Yuki

WEKO 458991

Kase, Yuki

Search repository
Matsumoto, Yoshitaka

× Matsumoto, Yoshitaka

WEKO 458992

Matsumoto, Yoshitaka

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 458993

Furusawa, Yoshiya

Search repository
Fujita, Yukio

× Fujita, Yukio

WEKO 458994

Fujita, Yukio

Search repository
Saitoh, Hidetoshi

× Saitoh, Hidetoshi

WEKO 458995

Saitoh, Hidetoshi

Search repository
Itami, Jun

× Itami, Jun

WEKO 458996

Itami, Jun

Search repository
Kohno, Toshiyuki

× Kohno, Toshiyuki

WEKO 458997

Kohno, Toshiyuki

Search repository
岡本 弘樹

× 岡本 弘樹

WEKO 458998

en 岡本 弘樹

Search repository
金井 達明

× 金井 達明

WEKO 458999

en 金井 達明

Search repository
松本 孔貴

× 松本 孔貴

WEKO 459000

en 松本 孔貴

Search repository
古澤 佳也

× 古澤 佳也

WEKO 459001

en 古澤 佳也

Search repository
藤田 幸男

× 藤田 幸男

WEKO 459002

en 藤田 幸男

Search repository
伊丹 純

× 伊丹 純

WEKO 459003

en 伊丹 純

Search repository
河野 俊之

× 河野 俊之

WEKO 459004

en 河野 俊之

Search repository
抄録
内容記述タイプ Abstract
内容記述 Our cell survival data showed the obvious dependence of RBE on photon energy: The RBE value for 200 kV X-rays was approximately 10% greater than those for mega-voltage photon beams. In radiation therapy using mega-voltage photon beams, the photon energy distribution outside the field is different with that in the radiation field because of a large number of low energy scattering photons. Hence, the RBE values outside the field become greater. To evaluate the increase in RBE, the method of deriving the RBE using the Microdosimetric Kinetic model (MK model) was proposed in this study. The MK model has two kinds of the parameters, tissue-specific parameters and the dose-mean lineal energy derived from the lineal energy distributions measured with a Tissue-Equivalent Proportional Counter (TEPC). The lineal energy distributions with the same geometries of the cell irradiations for 200 kV X-rays, 60Co ganma-rays, and 6 MV X-rays were obtained with the TEPC and Monte Carlo code GEANT4. The measured lineal energy distribution for 200 kV X-rays was quite different from those for mega-voltage photon beams. The dose-mean lineal energy of 200 kV X-rays showed the greatest value, 4.51 keV/micro-m, comparing with 2.34 and 2.36 keV/micro-m for 60Co ganma-rays and 6 MV X-rays, respectively. By using the results of the TEPC and cell irradiations, the tissue-specific parameters in the MK model were determined. As a result, the RBE of the photon beams (yD: 2~5 keV/micro-m) in arbitrary conditions can be derived by the measurements only or the calculations only of the dose-mean lineal energy.
書誌情報 Journal of Radiation Research

巻 52, 号 1, p. 75-81, 発行日 2010-12
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
DOI
識別子タイプ DOI
関連識別子 10.1269/jrr.10073
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:55:48.494183
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3