WEKO3
アイテム
{"_buckets": {"deposit": "fec4370b-1097-40e7-ad1e-da67425ddb88"}, "_deposit": {"created_by": 1, "id": "46083", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46083"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046083", "sets": ["1"]}, "author_link": ["458760", "458762", "458767", "458754", "458759", "458765", "458768", "458755", "458769", "458758", "458770", "458771", "458764", "458766", "458757", "458761", "458763", "458756"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "392", "bibliographicPageStart": "385", "bibliographicVolumeNumber": "51", "bibliographic_titles": [{"bibliographic_title": "Journal of Radiation Research"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In the last few years, hospital-based facilities for carbon-ion radiotherapy are being constructed and proposed in Europe and Asia. During the next few years, several new facilities will be opened for carbon-ion radiotherapy in the world. These facilities in operation or under construction are categorized in two types by the beam shaping method used. One is the passive beam shaping method that is mainly improved and systematized for routine clinical use at HIMAC, Japan. The other method is active beam shaping which is also known as beam scanning adopted at GSI/HIT, Germany. In this paper an overview of some technical aspects for beam shaping is reported. The technique of passive beam shaping is established for stable clinical application and has clinical result of over 4000 patients in HIMAC. In contrast, clinical experience of active beam shaping is about 400 patients, and there is no clinical experience to respiratory moving target. A great advantage of the active beam shaping method is patient-specific collimator-less and compensator-less treatment. This may be an interesting potential for adaptive radiotherapy.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1269/jrr.10028", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0449-3060", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Minohara, Shinichi"}], "nameIdentifiers": [{"nameIdentifier": "458754", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fukuda, Shigekazu"}], "nameIdentifiers": [{"nameIdentifier": "458755", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanematsu, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "458756", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takei, Yuka"}], "nameIdentifiers": [{"nameIdentifier": "458757", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furukawa, Takuji"}], "nameIdentifiers": [{"nameIdentifier": "458758", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inaniwa, Taku"}], "nameIdentifiers": [{"nameIdentifier": "458759", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsufuji, Naruhiro"}], "nameIdentifiers": [{"nameIdentifier": "458760", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mori, Shinichiro"}], "nameIdentifiers": [{"nameIdentifier": "458761", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Noda, Kouji"}], "nameIdentifiers": [{"nameIdentifier": "458762", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "蓑原 伸一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "458763", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福田 茂一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "458764", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "兼松 伸幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "458765", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武井 由佳", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "458766", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 卓司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "458767", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲庭 拓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "458768", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松藤 成弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "458769", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "458770", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "458771", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Recent Innovations in Carbon-Ion Radiotherapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Recent Innovations in Carbon-Ion Radiotherapy"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46083", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-05-28"}, "publish_date": "2011-05-28", "publish_status": "0", "recid": "46083", "relation": {}, "relation_version_is_last": true, "title": ["Recent Innovations in Carbon-Ion Radiotherapy"], "weko_shared_id": -1}
Recent Innovations in Carbon-Ion Radiotherapy
https://repo.qst.go.jp/records/46083
https://repo.qst.go.jp/records/46083a687a44a-9e8e-4584-b86a-866a7cfadbf9
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-05-28 | |||||
タイトル | ||||||
タイトル | Recent Innovations in Carbon-Ion Radiotherapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Minohara, Shinichi
× Minohara, Shinichi× Fukuda, Shigekazu× Kanematsu, Nobuyuki× Takei, Yuka× Furukawa, Takuji× Inaniwa, Taku× Matsufuji, Naruhiro× Mori, Shinichiro× Noda, Kouji× 蓑原 伸一× 福田 茂一× 兼松 伸幸× 武井 由佳× 古川 卓司× 稲庭 拓× 松藤 成弘× 森 慎一郎× 野田 耕司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In the last few years, hospital-based facilities for carbon-ion radiotherapy are being constructed and proposed in Europe and Asia. During the next few years, several new facilities will be opened for carbon-ion radiotherapy in the world. These facilities in operation or under construction are categorized in two types by the beam shaping method used. One is the passive beam shaping method that is mainly improved and systematized for routine clinical use at HIMAC, Japan. The other method is active beam shaping which is also known as beam scanning adopted at GSI/HIT, Germany. In this paper an overview of some technical aspects for beam shaping is reported. The technique of passive beam shaping is established for stable clinical application and has clinical result of over 4000 patients in HIMAC. In contrast, clinical experience of active beam shaping is about 400 patients, and there is no clinical experience to respiratory moving target. A great advantage of the active beam shaping method is patient-specific collimator-less and compensator-less treatment. This may be an interesting potential for adaptive radiotherapy. | |||||
書誌情報 |
Journal of Radiation Research 巻 51, 号 4, p. 385-392, 発行日 2010-07 |
|||||