  1. 原著論文

Characterization of FDG-PET images after stereotactic body radiation therapy for lung cancer.

https://repo.qst.go.jp/records/45998
https://repo.qst.go.jp/records/45998
10c90ebd-aafb-442b-9a87-7f713f15eccc
Item type 学術雑誌論文 / Journal Article(1)
公開日 2011-02-07
タイトル
タイトル Characterization of FDG-PET images after stereotactic body radiation therapy for lung cancer.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsuo, Yukinori

× Matsuo, Yukinori

WEKO 457768

Matsuo, Yukinori

Search repository
Nakamoto, Yuji

× Nakamoto, Yuji

WEKO 457769

Nakamoto, Yuji

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 457770

Saga, Tsuneo

Search repository
Higashi, Tatsuya

× Higashi, Tatsuya

WEKO 457771

Higashi, Tatsuya

Search repository
Togashi, Kaori

× Togashi, Kaori

WEKO 457772

Togashi, Kaori

Search repository
Hiraoka, Masahiro

× Hiraoka, Masahiro

WEKO 457773

Hiraoka, Masahiro

Search repository
et.al

× et.al

WEKO 457774

et.al

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 457775

en 佐賀 恒夫

Search repository
平岡 真寛

× 平岡 真寛

WEKO 457776

en 平岡 真寛

Search repository
抄録
内容記述タイプ Abstract
内容記述 BACKGROUND AND PURPOSE: The purpose was to characterize (18)F-fluorodeoxyglucose-positron emission tomography (FDG-PET) findings after stereotactic body radiation therapy (SBRT) for lung cancer. MATERIALS AND METHODS: This was a retrospective review of 32 FDG-PET scans from 23 patients who underwent SBRT for lung cancer and who showed no evidence of local recurrence. The FDG uptake by lesions was assessed visually using a 3-point scale (0, none or faint; 1, mild; or 2, moderate to intense), and the demarcation (ill- or well-defined) was evaluated. For semi-quantitative analysis, the maximum standardized uptake value (SUVmax) was calculated. RESULTS: Grade 2 intensity was observed in 70%, 33%, 30%, and 0% of PET scans performed <6, 6-12, 12-24, and >24months, respectively, after SBRT; well-defined demarcation was observed in 80%, 33%, 40%, and 17%, respectively, and the respective means of the SUVmax were 4.9, 2.6, 3.0, and 2.3. The SUVmax was significantly higher for scans performed at <6months than at 6-12 or >24months. CONCLUSIONS: FDG uptake tended to be intense and well-defined at early times after SBRT, especially within 6months, and was faint and ill-defined at later periods. Moderate to intense FDG uptake observed soon after SBRT does not always indicate a residual tumour. Copyright &copy; 2010 Elsevier Ireland Ltd. All rights reserved.
書誌情報 Radiotherapy and Oncology

巻 97, 号 2, p. 200-204, 発行日 2010-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0167-8140
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radonc.2010.04.011
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:57:06.032057
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3