WEKO3
アイテム
{"_buckets": {"deposit": "59171cc0-9b03-4007-ac5a-84e2859e03d3"}, "_deposit": {"created_by": 1, "id": "45992", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45992"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045992", "sets": ["1"]}, "author_link": ["457683", "457686", "457687", "457685", "457682", "457684"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "11", "bibliographicPageStart": "6", "bibliographicVolumeNumber": "631", "bibliographic_titles": [{"bibliographic_title": "Nuclear Instruments \u0026 Methods in Physics Research Section A"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "One approach for alpha-particle radiobiological experiments is to use solid-state nuclear track detectors (SSNTDs) as support substrates to record the \u0026#61537;-particle hit positions on the targets. To facilitate accurate characterization of the hit positions as well as the incident alpha-particle energies, micro-collimators are required in these experiments to restrict the incident \u0026#61537; particles to those with small deviations from normal incidence with respect to the collimator. In the present paper, we fabricated micro-collimators which restricted alpha-particles to those with deviations as low as 12o. Specially etched polyallyldiglycol carbonate (PADC) films, which are a kind of SSNTD, with a thickness 70 \u0026micro;m were prepared from commercially available PADC films. These were then irradiated by 4.83 MeV/n oxygen ions generated from the heavy-ion medical accelerator in Chiba (HIMAC), Japan. The irradiated films were chemically etched for at least 2.7 h to achieve etched-through air channels to form the micro-collimators. The micro-collimators formed by etching the irradiated films for 2.7, 3, 4 h were experimentally shown to be able to restrict alpha-particles to those very close to normal incidence, while that formed by etching the irradiated film for 4.5 h started to allow alpha-particles with larger deviations from normal incidence to pass through, the latter being likely due to overlapping of air channels from excessive etching.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.nima.2010.12.100", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0168-9002", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "W.Y., Choi Viann"}], "nameIdentifiers": [{"nameIdentifier": "457682", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ng, C.K.M."}], "nameIdentifiers": [{"nameIdentifier": "457683", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nikezic, Dragoslav"}], "nameIdentifiers": [{"nameIdentifier": "457684", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Konishi, Teruaki"}], "nameIdentifiers": [{"nameIdentifier": "457685", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "K.N., Yu Peter"}], "nameIdentifiers": [{"nameIdentifier": "457686", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小西 輝昭", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "457687", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Micro-collimators fabricated by chemical etching of thin polyallyldiglycol carbonate polymer films exposed to oxygen ions", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Micro-collimators fabricated by chemical etching of thin polyallyldiglycol carbonate polymer films exposed to oxygen ions"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45992", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-02-03"}, "publish_date": "2011-02-03", "publish_status": "0", "recid": "45992", "relation": {}, "relation_version_is_last": true, "title": ["Micro-collimators fabricated by chemical etching of thin polyallyldiglycol carbonate polymer films exposed to oxygen ions"], "weko_shared_id": -1}
Micro-collimators fabricated by chemical etching of thin polyallyldiglycol carbonate polymer films exposed to oxygen ions
https://repo.qst.go.jp/records/45992
https://repo.qst.go.jp/records/459927cc02146-d253-4792-a04e-ced649462989
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-02-03 | |||||
タイトル | ||||||
タイトル | Micro-collimators fabricated by chemical etching of thin polyallyldiglycol carbonate polymer films exposed to oxygen ions | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
W.Y., Choi Viann
× W.Y., Choi Viann× Ng, C.K.M.× Nikezic, Dragoslav× Konishi, Teruaki× K.N., Yu Peter× 小西 輝昭 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | One approach for alpha-particle radiobiological experiments is to use solid-state nuclear track detectors (SSNTDs) as support substrates to record the -particle hit positions on the targets. To facilitate accurate characterization of the hit positions as well as the incident alpha-particle energies, micro-collimators are required in these experiments to restrict the incident  particles to those with small deviations from normal incidence with respect to the collimator. In the present paper, we fabricated micro-collimators which restricted alpha-particles to those with deviations as low as 12o. Specially etched polyallyldiglycol carbonate (PADC) films, which are a kind of SSNTD, with a thickness 70 µm were prepared from commercially available PADC films. These were then irradiated by 4.83 MeV/n oxygen ions generated from the heavy-ion medical accelerator in Chiba (HIMAC), Japan. The irradiated films were chemically etched for at least 2.7 h to achieve etched-through air channels to form the micro-collimators. The micro-collimators formed by etching the irradiated films for 2.7, 3, 4 h were experimentally shown to be able to restrict alpha-particles to those very close to normal incidence, while that formed by etching the irradiated film for 4.5 h started to allow alpha-particles with larger deviations from normal incidence to pass through, the latter being likely due to overlapping of air channels from excessive etching. | |||||
書誌情報 |
Nuclear Instruments & Methods in Physics Research Section A 巻 631, 号 1, p. 6-11, 発行日 2010-12 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-9002 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nima.2010.12.100 |