WEKO3
アイテム
Comparison of efficacy and toxicity of short-course carbon ion radiotherapy for hepatocellular carcinoma depending on their proximity to the porta hepatis
https://repo.qst.go.jp/records/45964
https://repo.qst.go.jp/records/459643abf34fd-3026-4b53-aa14-e9bcb1fe1080
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2010-12-13 | |||||
| タイトル | ||||||
| タイトル | Comparison of efficacy and toxicity of short-course carbon ion radiotherapy for hepatocellular carcinoma depending on their proximity to the porta hepatis | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
Imada, Hiroshi
× Imada, Hiroshi× Katou, Hirotoshi× Yasuda, Shigeo× Yamada, Shigeru× Yanagi, Takeshi× Kishimoto, Riwa× Kandatsu, Susumu× Mizoe, Junetsu× Kamada, Tadashi× Yokosuka, Osamu× Tsujii, Hirohiko× 今田 浩史× 加藤 博敏× 安田 茂雄× 山田 滋× 柳 剛× 岸本 理和× 神立 進× 溝江 純悦× 鎌田 正× 横須賀 収× 辻井 博彦 |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | Background and purpose:To compare the efficacy and toxicity of short-course carbon ion radiotherapy (C-ion RT) for patients with hepatocellular carcinoma (HCC) in terms of tumor location: adjacent to the porta hepatis or not. Materials and methods:The study consisted of 64 patients undergoing C-ion RT of 52.8 GyE in four fractions between April 2000 and March 2003. Of these patients, 18 had HCC located within 2 cm of the main portal vein (porta hepatis group) and 46 patients had HCC far from the porta hepatis (non-porta hepatis group). We compared local control, survival, and adverse events between the two groups. Results:The 5-year overall survival and local control rates were 22.2% and 87.8% in the porta hepatis group and 34.8% and 95.7% in the non-porta hepatis group, respectively. There were no significant differences (P = 0.252, P = 0.306, respectively). Further, there were no significant differences in toxicities. Biliary stricture associated with C-ion RT did not occur. Conclusions:Excellent local control was obtained independent of tumor location. The short-course C-ion RT of 52.8 GyE in four fractions appears to be an effective and safe treatment modality in the porta hepatis group just as in the non-porta hepatis group. |
|||||
| 書誌情報 |
Radiotherapy and Oncology 巻 96, 号 2, p. 231-235, 発行日 2010-08 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0167-8140 | |||||