ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Effect of Carbon Ion Radiotherapy for Sacral Chordoma: Results of Phase I-II and Phase II Clinical Trials

https://repo.qst.go.jp/records/45863
https://repo.qst.go.jp/records/45863
3ebb80a8-5a50-4c75-b7ce-c0e1af86e82a
Item type 学術雑誌論文 / Journal Article(1)
公開日 2010-07-23
タイトル
タイトル Effect of Carbon Ion Radiotherapy for Sacral Chordoma: Results of Phase I-II and Phase II Clinical Trials
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Imai, Reiko

× Imai, Reiko

WEKO 456158

Imai, Reiko

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 456159

Kamada, Tadashi

Search repository
Tsuji, Hiroshi

× Tsuji, Hiroshi

WEKO 456160

Tsuji, Hiroshi

Search repository
Sugahara, Shinji

× Sugahara, Shinji

WEKO 456161

Sugahara, Shinji

Search repository
Serizawa, Itsuko

× Serizawa, Itsuko

WEKO 456162

Serizawa, Itsuko

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 456163

Tsujii, Hirohiko

Search repository
Tatezaki, Shinichiroh

× Tatezaki, Shinichiroh

WEKO 456164

Tatezaki, Shinichiroh

Search repository
今井 礼子

× 今井 礼子

WEKO 456165

en 今井 礼子

Search repository
鎌田 正

× 鎌田 正

WEKO 456166

en 鎌田 正

Search repository
辻 比呂志

× 辻 比呂志

WEKO 456167

en 辻 比呂志

Search repository
菅原 信二

× 菅原 信二

WEKO 456168

en 菅原 信二

Search repository
芹澤 慈子

× 芹澤 慈子

WEKO 456169

en 芹澤 慈子

Search repository
辻井 博彦

× 辻井 博彦

WEKO 456170

en 辻井 博彦

Search repository
舘崎 愼一郎

× 舘崎 愼一郎

WEKO 456171

en 舘崎 愼一郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 PURPOSE: To summarize the results of treatment for sacral chordoma in Phase I-II and Phase II carbon ion radiotherapy trials for bone and soft-tissue sarcomas. PATIENTS AND METHODS: We performed a retrospective analysis of 38 patients with medically unresectable sacral chordomas treated with the Heavy Ion Medical Accelerator in Chiba, Japan between 1996 and 2003. Of the 38 patients, 30 had not received previous treatment and 8 had locally recurrent tumor after previous resection. The applied carbon ion dose was 52.8-73.6 Gray equivalents (median, 70.4) in a total of 16 fixed fractions within 4 weeks. RESULTS: The median patient age was 66 years. The cranial tumor extension was S2 or greater in 31 patients. The median clinical target volume was 523 cm(3). The median follow-up period was 80 months. The 5-year overall survival rate was 86%, and the 5-year local control rate was 89%. After treatment, 27 of 30 patients with primary tumor remained ambulatory with or without supportive devices. Two patients experienced severe skin or soft-tissue complications requiring skin grafts. CONCLUSION: Carbon ion radiotherapy appears effective and safe in the treatment of patients with sacral chordoma and offers a promising alternative to surgery.
書誌情報 International Journal of Radiation Oncology Biology Physics

巻 77, 号 5, p. 1470-1476, 発行日 2009-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0360-3016
DOI
識別子タイプ DOI
関連識別子 10.1016/j-ijrobp.2009.06.048
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:58:41.464096
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3