WEKO3
アイテム
{"_buckets": {"deposit": "bcd9086c-1170-4397-b1bb-65cbb41ef720"}, "_deposit": {"created_by": 1, "id": "45716", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45716"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045716", "sets": ["1"]}, "author_link": ["454420", "454418", "454416", "454422", "454421", "454417", "454423", "454419"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "9-10", "bibliographicPageEnd": "908", "bibliographicPageStart": "905", "bibliographicVolumeNumber": "44", "bibliographic_titles": [{"bibliographic_title": "Radiation Measurements"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A significant obstacle to long duration human space exploration such as the establishment of a permanent base on the surface of the Moon or a human mission to Mars is the risk posed by prolonged exposure to space radiation. In order to keep mission costs at acceptable levels while simultaneously minimizing the risk from diation to space crew health and safety, a judicious use of optimized shielding materials will be required.We have undertaken a comprehensive study using CR-39 plastic nuclear track detector (PNTD) to characterize the radiation shielding properties of a range of materialsdboth common baseline materials such as Al and polyethylene, and novel multifunctional materials such as carbon compositesdat heavy ion accelerators. The study consists of analyzing CR-39 PNTD exposed in front of and behind shielding targets of varying composition and at a number of depths (target thicknesses) relevant to the development and testing of materials for space radiation shielding. Most targets consist of 10 cm* 10 cm slabs of solid materials ranging in thickness from 1 to \u003e30 g/cm2. Exposures have been made to beams of C, O, Ne, Si, Ar, and Fe at energies ranging from 290 MeV/amu to 1 GeV/amu at the National Institute of Radiological Sciences HIMAC and the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory. Analysis of the exposed detectors yields LET spectrum, dose, and dose equivalent as functions of target depth and composition, and incident heavy ion charge, energy, and fluence. Efforts are currently underway to properly weigh and combine these results into a single quantitative estimate of a material\u0027s ability to shield space crews from the interplanetary galactic cosmic ray flux.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1350-4487", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "DeWitt, Joel"}], "nameIdentifiers": [{"nameIdentifier": "454416", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Benton, Eric"}], "nameIdentifiers": [{"nameIdentifier": "454417", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uchihori, Yukio"}], "nameIdentifiers": [{"nameIdentifier": "454418", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yasuda, Nakahiro"}], "nameIdentifiers": [{"nameIdentifier": "454419", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Benton, Eugene"}], "nameIdentifiers": [{"nameIdentifier": "454420", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "454421", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内堀 幸夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454422", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安田 仲宏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454423", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Assessment of radiation shielding materials for protection of space crews using CR-39 plastic nuclear track detector", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Assessment of radiation shielding materials for protection of space crews using CR-39 plastic nuclear track detector"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45716", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-01-05"}, "publish_date": "2010-01-05", "publish_status": "0", "recid": "45716", "relation": {}, "relation_version_is_last": true, "title": ["Assessment of radiation shielding materials for protection of space crews using CR-39 plastic nuclear track detector"], "weko_shared_id": -1}
Assessment of radiation shielding materials for protection of space crews using CR-39 plastic nuclear track detector
https://repo.qst.go.jp/records/45716
https://repo.qst.go.jp/records/457160f2f54fa-57d3-4564-aca9-bd00e539ba54
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-01-05 | |||||
タイトル | ||||||
タイトル | Assessment of radiation shielding materials for protection of space crews using CR-39 plastic nuclear track detector | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
DeWitt, Joel
× DeWitt, Joel× Benton, Eric× Uchihori, Yukio× Yasuda, Nakahiro× Benton, Eugene× et.al× 内堀 幸夫× 安田 仲宏 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A significant obstacle to long duration human space exploration such as the establishment of a permanent base on the surface of the Moon or a human mission to Mars is the risk posed by prolonged exposure to space radiation. In order to keep mission costs at acceptable levels while simultaneously minimizing the risk from diation to space crew health and safety, a judicious use of optimized shielding materials will be required.We have undertaken a comprehensive study using CR-39 plastic nuclear track detector (PNTD) to characterize the radiation shielding properties of a range of materialsdboth common baseline materials such as Al and polyethylene, and novel multifunctional materials such as carbon compositesdat heavy ion accelerators. The study consists of analyzing CR-39 PNTD exposed in front of and behind shielding targets of varying composition and at a number of depths (target thicknesses) relevant to the development and testing of materials for space radiation shielding. Most targets consist of 10 cm* 10 cm slabs of solid materials ranging in thickness from 1 to >30 g/cm2. Exposures have been made to beams of C, O, Ne, Si, Ar, and Fe at energies ranging from 290 MeV/amu to 1 GeV/amu at the National Institute of Radiological Sciences HIMAC and the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory. Analysis of the exposed detectors yields LET spectrum, dose, and dose equivalent as functions of target depth and composition, and incident heavy ion charge, energy, and fluence. Efforts are currently underway to properly weigh and combine these results into a single quantitative estimate of a material's ability to shield space crews from the interplanetary galactic cosmic ray flux. | |||||
書誌情報 |
Radiation Measurements 巻 44, 号 9-10, p. 905-908, 発行日 2009-10 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1350-4487 |