Body-contour versus circular orbit acquisition in cardiac SPECT: Assessment of defect detectability with channelized Hotelling observer

https://repo.qst.go.jp/records/45075
https://repo.qst.go.jp/records/45075
e663cfb4-8a34-4f96-8630-3c2ef04665e6
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-01-10
タイトル
タイトル Body-contour versus circular orbit acquisition in cardiac SPECT: Assessment of defect detectability with channelized Hotelling observer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Watabe, Hiroshi

× Watabe, Hiroshi

WEKO 447588

Watabe, Hiroshi

Search repository
Shidahara, Miho

× Shidahara, Miho

WEKO 447589

Shidahara, Miho

Search repository
Iida, Hidehiro

× Iida, Hidehiro

WEKO 447590

Iida, Hidehiro

Search repository
et.al

× et.al

WEKO 447591

et.al

Search repository
渡部 浩司

× 渡部 浩司

WEKO 447592

en 渡部 浩司

Search repository
志田原 美保

× 志田原 美保

WEKO 447593

en 志田原 美保

Search repository
飯田 秀博

× 飯田 秀博

WEKO 447594

en 飯田 秀博

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background The resolution of a gamma camera is depthdependentand worsens with increasing distance to the camera resulting in a loss of fine details in SPECT images. A common approach to reduce the effects of this resolution loss is to utilize body-contour acquisition orbits. Even though body-contour orbits can improve resolution of reconstructed images their effect on lesion detection is not well known. Objective To investigate whether body-contour orbits offer better defect detection performance than circular orbits in cardiac SPECT. Methods The athematical cardiac torso (MCAT) phantom was used to model 99mTc-sestamibi uptake. A total of four phantoms (two male and two female) with eight defects (four locations and two sizes) were generated and projection data were simulated using an analytical projector with attenuation, scatter, collimator response and acquisition orbit modelling. The circular and body-contour projections were reconstructed using the OSEM algorithm with/without collimator response compensation. Defect detection performance was assessed by calculating area under the receiver operating characteristic (ROC) curve for channelized Hotelling observer. Results The defect detection performance of circular and body-contour acquisition was very similar and the difference in the area under the ROC curve between the orbits was not statistically significant with or without collimator response compensation. The collimator response compensation, on the other hand, was noticed to be valuable and it provided significantly better defect detection performance than reconstruction without it regardless of the acquisition orbit type. Conclusions We conclude that by replacing circular orbit with more complex body-contour orbit will not lead to
statistically significant increase in defect detection performance in cardiac SPECT.
書誌情報 Nuclear Medicine Communications

巻 28, 号 12, p. 937-942, 発行日 2007-12
ISSN
収録物識別子タイプ ISSN
収録物識別子 0143-3636
戻る
0
views
See details
Views