  1. 原著論文

Development and performance evaluation of the second model 256-detector row CT

https://repo.qst.go.jp/records/45069
https://repo.qst.go.jp/records/45069
d54e8605-7d99-4b06-b716-6d43f502d604
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-01-08
タイトル
タイトル Development and performance evaluation of the second model 256-detector row CT
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Endo, Masahiro

× Endo, Masahiro

WEKO 447534

Endo, Masahiro

Search repository
Mori, Shinichiro

× Mori, Shinichiro

WEKO 447535

Mori, Shinichiro

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 447536

Kandatsu, Susumu

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 447537

Tanada, Shuji

Search repository
Kondo, Chisato

× Kondo, Chisato

WEKO 447538

Kondo, Chisato

Search repository
遠藤 真広

× 遠藤 真広

WEKO 447539

en 遠藤 真広

Search repository
森 慎一郎

× 森 慎一郎

WEKO 447540

en 森 慎一郎

Search repository
神立 進

× 神立 進

WEKO 447541

en 神立 進

Search repository
棚田 修二

× 棚田 修二

WEKO 447542

en 棚田 修二

Search repository
近藤 千里

× 近藤 千里

WEKO 447543

en 近藤 千里

Search repository
抄録
内容記述タイプ Abstract
内容記述 Since our initial development of the 256-detector row CT scanner (256-row CT) for four-dimensional (4D) imaging of moving organs in 2003, the results of physical performance and those in animal and human studies have suggested that this scanner may be useful in the examination of moving organs such as the heart and lungs. We have now developed a second model of the 256-row CT with improved specifications, with a scan time of 0.5 s/rotation at the highest speed and real-time reconstruction and display of dynamic 3D images (4D images). Here, we investigated the image characteristics of the new model, including spatial resolution, noise, and low-contrast detectability, as well as the dose profile and its integral in stationary phantoms. One volunteer and one patient with lung cancer were scanned, and their images were evaluated. The results show that all characteristics have been improved compared with those of the first model, with a remarkable improvement in the low-contrast detectability and slice sensitivity profile. In a contrast study, coronary arteries were clearly visualized in the normal heart without electrocardiographic gating. Movement and deformation of the tumor in the patient with lung cancer was captured in a study of a single breath cycle. The second model 256-row CT with improved characteristics may be beneficial in imaging of moving organs such as the heart and lungs, and may enable cerebral perfusion studies of the whole brain.
書誌情報 Radiological Physics and Technology

巻 1, 号 1, p. 20-26, 発行日 2007-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 1865-0333
DOI
識別子タイプ DOI
関連識別子 10.1007/s12194-007-0004-z
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:08:03.969572
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3