WEKO3
アイテム
{"_buckets": {"deposit": "869bde80-14d6-4cb0-9bdb-9be5cb57f588"}, "_deposit": {"created_by": 1, "id": "44924", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44924"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044924", "sets": ["1"]}, "author_link": ["446169", "446173", "446172", "446168", "446167", "446171", "446170"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "310", "bibliographicPageStart": "307", "bibliographicVolumeNumber": "273", "bibliographic_titles": [{"bibliographic_title": "Journal of Radioanalytical and Nuclear Chemistry"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Rapid analysis for Sr-90, Th-232, and U-238 in human urine samples collected in a radiation emergency can be developed by co-precipitation with calcium phosphate and separation using a Sr-resin (Eichrom Technologies, Inc.) column. The nuclides were measured by inductively coupled plasma mass spectrometry (ICP-MS) or a low background beta-counter. Spike tests yielded a good recovery of above 90%. Fractions of Sr-90 and the other nuclides (Th-232 and U-238) were separated in about 2 hours. It was judged that the developed method would be an effective bioassay method in radiation emergency.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0236-5731", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Shiraishi, Kunio"}], "nameIdentifiers": [{"nameIdentifier": "446167", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ko, Susumu"}], "nameIdentifiers": [{"nameIdentifier": "446168", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Arae, Hideki"}], "nameIdentifiers": [{"nameIdentifier": "446169", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ayama, Kyoko"}], "nameIdentifiers": [{"nameIdentifier": "446170", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白石 久二雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "446171", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "幸 進", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "446172", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "阿山 香子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "446173", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Rapid analysis technique for strontium, torium, and uranium in urine samples", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Rapid analysis technique for strontium, torium, and uranium in urine samples"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44924", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-07-26"}, "publish_date": "2007-07-26", "publish_status": "0", "recid": "44924", "relation": {}, "relation_version_is_last": true, "title": ["Rapid analysis technique for strontium, torium, and uranium in urine samples"], "weko_shared_id": -1}
Rapid analysis technique for strontium, torium, and uranium in urine samples
https://repo.qst.go.jp/records/44924
https://repo.qst.go.jp/records/44924da46f94e-ecf3-4f8a-80b2-d5e93bdfa4f3
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-07-26 | |||||
タイトル | ||||||
タイトル | Rapid analysis technique for strontium, torium, and uranium in urine samples | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Shiraishi, Kunio
× Shiraishi, Kunio× Ko, Susumu× Arae, Hideki× Ayama, Kyoko× 白石 久二雄× 幸 進× 阿山 香子 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Rapid analysis for Sr-90, Th-232, and U-238 in human urine samples collected in a radiation emergency can be developed by co-precipitation with calcium phosphate and separation using a Sr-resin (Eichrom Technologies, Inc.) column. The nuclides were measured by inductively coupled plasma mass spectrometry (ICP-MS) or a low background beta-counter. Spike tests yielded a good recovery of above 90%. Fractions of Sr-90 and the other nuclides (Th-232 and U-238) were separated in about 2 hours. It was judged that the developed method would be an effective bioassay method in radiation emergency. | |||||
書誌情報 |
Journal of Radioanalytical and Nuclear Chemistry 巻 273, 号 2, p. 307-310, 発行日 2007 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0236-5731 |