WEKO3
アイテム
{"_buckets": {"deposit": "a5e48e67-cf1e-49c8-b87e-f8ff6f37e29e"}, "_deposit": {"created_by": 1, "id": "44859", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44859"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044859", "sets": ["1"]}, "author_link": ["445479", "445480", "445483", "445481", "445482", "445478"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "214", "bibliographicPageStart": "211", "bibliographicVolumeNumber": "273", "bibliographic_titles": [{"bibliographic_title": "Journal of Radioanalytical and Nuclear Chemistry"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "An online analytical system using ion chromatography (IC) followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the separate determination of I- and IO3- in aqueous solutions with a detection limit 0.1 - 1 ?g-I/L. The total iodine concentration was also directly determined by ICP-MS. Iodine in several environmental samples (i.e. rain, river water, brine, and soil solution) was successfully determined with information on chemical form. The release of I- into soil solution with decreasing Eh was observed in an incubation experiment with flooded soil. An iodine form other than I- and IO3- was observed in several environmental samples.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0236-5731", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yoshida, Satoshi"}], "nameIdentifiers": [{"nameIdentifier": "445478", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Muramatsu, Yasuyuki"}], "nameIdentifiers": [{"nameIdentifier": "445479", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kato, Shota"}], "nameIdentifiers": [{"nameIdentifier": "445480", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sekimoto, Hitoshi"}], "nameIdentifiers": [{"nameIdentifier": "445481", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 聡", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445482", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加藤 翔太", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445483", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Determination of the chemical forms of iodine with IC-ICP-MS and its application to environmental samples", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Determination of the chemical forms of iodine with IC-ICP-MS and its application to environmental samples"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44859", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-05-29"}, "publish_date": "2007-05-29", "publish_status": "0", "recid": "44859", "relation": {}, "relation_version_is_last": true, "title": ["Determination of the chemical forms of iodine with IC-ICP-MS and its application to environmental samples"], "weko_shared_id": -1}
Determination of the chemical forms of iodine with IC-ICP-MS and its application to environmental samples
https://repo.qst.go.jp/records/44859
https://repo.qst.go.jp/records/448596904e423-66ae-4cce-94e9-15bc2c7e53bd
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-05-29 | |||||
タイトル | ||||||
タイトル | Determination of the chemical forms of iodine with IC-ICP-MS and its application to environmental samples | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yoshida, Satoshi
× Yoshida, Satoshi× Muramatsu, Yasuyuki× Kato, Shota× Sekimoto, Hitoshi× 吉田 聡× 加藤 翔太 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | An online analytical system using ion chromatography (IC) followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the separate determination of I- and IO3- in aqueous solutions with a detection limit 0.1 - 1 ?g-I/L. The total iodine concentration was also directly determined by ICP-MS. Iodine in several environmental samples (i.e. rain, river water, brine, and soil solution) was successfully determined with information on chemical form. The release of I- into soil solution with decreasing Eh was observed in an incubation experiment with flooded soil. An iodine form other than I- and IO3- was observed in several environmental samples. | |||||
書誌情報 |
Journal of Radioanalytical and Nuclear Chemistry 巻 273, 号 1, p. 211-214, 発行日 2007-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0236-5731 |