ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Quantitative mapping of basal and vasareactive cerebral blood flow using split-dose 123I-iodoamphetamine and single photon emission computed tomography

https://repo.qst.go.jp/records/44804
https://repo.qst.go.jp/records/44804
1b93a757-1f10-445b-975e-9a8ad323594c
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-03-08
タイトル
タイトル Quantitative mapping of basal and vasareactive cerebral blood flow using split-dose 123I-iodoamphetamine and single photon emission computed tomography
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Watabe, Hiroshi

× Watabe, Hiroshi

WEKO 444890

Watabe, Hiroshi

Search repository
Shidahara, Miho

× Shidahara, Miho

WEKO 444891

Shidahara, Miho

Search repository
Iida, Hidehiro

× Iida, Hidehiro

WEKO 444892

Iida, Hidehiro

Search repository
et.al

× et.al

WEKO 444893

et.al

Search repository
渡部 浩司

× 渡部 浩司

WEKO 444894

en 渡部 浩司

Search repository
志田原 美保

× 志田原 美保

WEKO 444895

en 志田原 美保

Search repository
飯田 秀博

× 飯田 秀博

WEKO 444896

en 飯田 秀博

Search repository
抄録
内容記述タイプ Abstract
内容記述 A new method has been developed for diffusible tracers, to quantify CBF at rest and after pharmacological stress from a single session of dynamic scans with dual bolus administration of a radiotracer. The calculation process consisted of three steps, including the procedures of incorporating background radioactivity contaminated from the previous scan. Feasibility of this approach was tested on clinical SPECT studies on 16 subjects. Two sequential SPECT scans, 30 min apart, were carried out on each subject, after each of two splitdose administrations of 111 MBq IMP. Of these, 11 subjects received acetazolamide at 10 min before the second IMP injection. Additional PET scans were also carried out on 6 subjects on a separate day, at rest and after acetazolamide administration. The other 5 subjects were scanned only at rest during the whole study period. Quantitative CBF obtained by this method was in a good agreement with those determined with PET (y(ml/100 g/min)=1.07%*(ml/100 g/min)-1.14, r=0.94). Vasareactivity was approximately 40% over the whole cerebral area on healthy controls, which was consistent with a literature value. Reproducibility of CBF determined in the rest–rest study was 1.5+/-5.7%. Noise enhancement of CBF images, particularly the second CBF, was reduced, providing reasonable image quality.
Repeat assessment of quantitative CBF from a single session of scans with split-dose IMP is accurate, and may be applied to clinical research for assessing vascular reactivity in patients with chronic cerebral vascular disease.
書誌情報 NeuroImage

巻 33, 号 4, p. 1126-1135, 発行日 2006-12
ISSN
収録物識別子タイプ ISSN
収録物識別子 1053-8119
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:11:09.565457
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3