WEKO3
アイテム
{"_buckets": {"deposit": "1793f9dd-6440-41b8-bdb3-8e84abb6ac42"}, "_deposit": {"created_by": 1, "id": "44796", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44796"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044796", "sets": ["1"]}, "author_link": ["444806", "444801", "444802", "444797", "444809", "444803", "444807", "444798", "444800", "444808", "444805", "444796", "444799", "444804"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1/2", "bibliographicPageEnd": "246", "bibliographicPageStart": "243", "bibliographicVolumeNumber": "571", "bibliographic_titles": [{"bibliographic_title": "Nuclear Instruments \u0026 Methods in Physics Research Section A"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In a conventional positron emission tomography (PET) detector, detected events are projected onto a 2D position histogram by an Anger calculation for crystal identification. However, the measured histogram is affected by inter-crystal scatterings (ICS) which occur in the entire detector. Peaks which are projected for each crystal in the histogram are blurred, and this causes ICS mispositioning. A depth-of-interaction (DOI) detector has been developed for the small animal PET scanner jPET-RD. This DOI detector uses 32*32 crystals with four layers and a 256-channel multi-anode flat panel photomultiplier tube (FP-PMT) which was developed by Hamamatsu Photonics K.K. Each crystal element is 1.45*1.45*4.5mm3. The FP-PMT has a large detective area (49*49mm2) and a small anode pitch (3.04 mm). Therefore, the FP-PMT can extensively trace the behavior of incident g rays in the crystals including ICS event. We, therefore, propose a novel method for ICS estimation using a statistical pattern recognition algorithm based on a support vector machine (SVM). In this study, we applied the SVM for discriminating photoelectric events from ICS events generated from multiple-anode outputs. The SVM was trained by uniform irradiation events generated from a detector simulator using a Monte Carlo calculation. The success rate for ICS event identification is about 78% for non-training data. The SVM can achieve a true subtraction of ICS events from measured events, and it is also useful for random correction in PET.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0168-9002", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yoshida, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "444796", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitamura, Keishi"}], "nameIdentifiers": [{"nameIdentifier": "444797", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kimura, Yuichi"}], "nameIdentifiers": [{"nameIdentifier": "444798", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishikido, Fumihiko"}], "nameIdentifiers": [{"nameIdentifier": "444799", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shibuya, Kengo"}], "nameIdentifiers": [{"nameIdentifier": "444800", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "444801", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murayama, Hideo"}], "nameIdentifiers": [{"nameIdentifier": "444802", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 英治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444803", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北村 圭司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444804", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "木村 裕一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444805", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "錦戸 文彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444806", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "澁谷 憲悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444807", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷 泰賀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444808", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村山 秀雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444809", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Inter-crystal scatter identification for a depth-sensitive detector using support vector machine for small animal positron emission tomography", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Inter-crystal scatter identification for a depth-sensitive detector using support vector machine for small animal positron emission tomography"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44796", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-02-22"}, "publish_date": "2007-02-22", "publish_status": "0", "recid": "44796", "relation": {}, "relation_version_is_last": true, "title": ["Inter-crystal scatter identification for a depth-sensitive detector using support vector machine for small animal positron emission tomography"], "weko_shared_id": -1}
Inter-crystal scatter identification for a depth-sensitive detector using support vector machine for small animal positron emission tomography
https://repo.qst.go.jp/records/44796
https://repo.qst.go.jp/records/44796d4e89984-05b0-45ea-b75b-a43c20babff1
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-02-22 | |||||
タイトル | ||||||
タイトル | Inter-crystal scatter identification for a depth-sensitive detector using support vector machine for small animal positron emission tomography | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yoshida, Eiji
× Yoshida, Eiji× Kitamura, Keishi× Kimura, Yuichi× Nishikido, Fumihiko× Shibuya, Kengo× Yamaya, Taiga× Murayama, Hideo× 吉田 英治× 北村 圭司× 木村 裕一× 錦戸 文彦× 澁谷 憲悟× 山谷 泰賀× 村山 秀雄 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In a conventional positron emission tomography (PET) detector, detected events are projected onto a 2D position histogram by an Anger calculation for crystal identification. However, the measured histogram is affected by inter-crystal scatterings (ICS) which occur in the entire detector. Peaks which are projected for each crystal in the histogram are blurred, and this causes ICS mispositioning. A depth-of-interaction (DOI) detector has been developed for the small animal PET scanner jPET-RD. This DOI detector uses 32*32 crystals with four layers and a 256-channel multi-anode flat panel photomultiplier tube (FP-PMT) which was developed by Hamamatsu Photonics K.K. Each crystal element is 1.45*1.45*4.5mm3. The FP-PMT has a large detective area (49*49mm2) and a small anode pitch (3.04 mm). Therefore, the FP-PMT can extensively trace the behavior of incident g rays in the crystals including ICS event. We, therefore, propose a novel method for ICS estimation using a statistical pattern recognition algorithm based on a support vector machine (SVM). In this study, we applied the SVM for discriminating photoelectric events from ICS events generated from multiple-anode outputs. The SVM was trained by uniform irradiation events generated from a detector simulator using a Monte Carlo calculation. The success rate for ICS event identification is about 78% for non-training data. The SVM can achieve a true subtraction of ICS events from measured events, and it is also useful for random correction in PET. | |||||
書誌情報 |
Nuclear Instruments & Methods in Physics Research Section A 巻 571, 号 1/2, p. 243-246, 発行日 2007-02 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-9002 |