  1. 原著論文

Candidate Image Processing for Real-time Volumetric CT Subtraction Angiography

https://repo.qst.go.jp/records/44784
https://repo.qst.go.jp/records/44784
ce625703-f9b2-407f-a135-97ed226b9ce7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2007-02-09
タイトル
タイトル Candidate Image Processing for Real-time Volumetric CT Subtraction Angiography
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 444688

Mori, Shinichiro

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 444689

Endo, Masahiro

Search repository
森 慎一郎

× 森 慎一郎

WEKO 444690

en 森 慎一郎

Search repository
遠藤 真広

× 遠藤 真広

WEKO 444691

en 遠藤 真広

Search repository
抄録
内容記述タイプ Abstract
内容記述 Since a 256-slice CT can perform real time observation of the volumetric cine images at multiple angles, volumetric CT angiography can provide much useful clinical information. Conventional CT subtraction angiography is generated by subtracting the non-enhanced CT image (mask CT image) from each contrast-enhanced CT image. Since even conventional CT subtraction angiography takes a few minutes to compute the image, volumetric CT subtraction angiography images require computation of an enormous amount of volumetric cine data (image base CT subtraction angiography: ICTSA) which means an excessively long calculating time. To reduce calculating time, we developed the raw data base CT subtraction angiography (RCTSA) that subtracts raw data instead of the reconstructed four-dimensional image sets. Image quality of the two image processing methods was evaluated in phantom and animal studies. Evaluation items were image noise, CT number uniformity, and subtracting RCTSA from ICTSA. ICTSA calculates the number of volume data; however, RCTSA uses the number of CT rotations. Moreover since RCTSA can also be started subtraction early in the process of data acquisition, it reduced the number of calculations considerably. As there is a longer CT acquisition time, RCTSA shortens the ratio of the calculating time compared to that of ICTSA. RCTSA is useful image processing to reduce CT subtraction angiography examination time instead of ICTSA.
書誌情報 European Journal of Radiology

巻 61, 号 2, p. 335-341, 発行日 2007-02
ISSN
収録物識別子タイプ ISSN
収録物識別子 0720-048X
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:11:22.810253
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3