{"_buckets": {"deposit": "42679729-2cc2-4642-b2fb-60e95dc9b920"}, "_deposit": {"created_by": 1, "id": "44373", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44373"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044373", "sets": ["1"]}, "author_link": ["440929", "440922", "440928", "440925", "440926", "440923", "440927", "440930", "440924"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1998", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "12", "bibliographicPageStart": "7", "bibliographicVolumeNumber": "16", "bibliographic_titles": [{"bibliographic_title": "Radiation Medicine"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We describe the design and implementation of a system that acquires three-dimensional (3D) data of high-contrast objects such as bone, lung, and blood vessels (enhanced by contrast agent). This 3D computed tomography (CT) system is based on a cone beam and video-fluoroscopic system and yields data that is amenable to 3D image processing. An X-ray tube and a large area two-dimensional detector were mounted on a single frame and rotated around objects in 12 seconds. The large area detector consisted of a fluorescent plate and a charge coupled device (CCD) video camera. While tha X-ray tube was rotated around the object, a pulsed X-ray was generated (30 pulses per second) and 360 projected images were collected in a 12-second scan. A 256x256x256 matrix image was reconstructed using a high-speed parallel processor. Reconstruction required approximately 6 minutes. Two volunteers under-went scans of the head or chest. High-contrast objects such as bronchial, vascular, and mediastinal structures in the thorax, or bones ans air cavities in the head were delineated in a \"real\" 3D format. Our 3D CT-scanner appears to produce data useful for clinical imaging and 3D image processing.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0288-2043", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "遠藤, 真広"}], "nameIdentifiers": [{"nameIdentifier": "440922", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田, 勝哉"}], "nameIdentifiers": [{"nameIdentifier": "440923", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "日下部, 正宏"}], "nameIdentifiers": [{"nameIdentifier": "440924", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "舘野, 之男"}], "nameIdentifiers": [{"nameIdentifier": "440925", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "その他"}], "nameIdentifiers": [{"nameIdentifier": "440926", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "遠藤 真広", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440927", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 勝哉", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440928", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "日下部 正宏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440929", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "舘野 之男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440930", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Development of a 3D CT-Scanner Using a Cone Beam and Video-Fluoroscopic System", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of a 3D CT-Scanner Using a Cone Beam and Video-Fluoroscopic System"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44373", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-06-29"}, "publish_date": "2006-06-29", "publish_status": "0", "recid": "44373", "relation": {}, "relation_version_is_last": true, "title": ["Development of a 3D CT-Scanner Using a Cone Beam and Video-Fluoroscopic System"], "weko_shared_id": -1}
Development of a 3D CT-Scanner Using a Cone Beam and Video-Fluoroscopic System
https://repo.qst.go.jp/records/44373
https://repo.qst.go.jp/records/4437327803cfa-6ad4-46c8-9961-9667b2c31ada
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-06-29 | |||||
タイトル | ||||||
タイトル | Development of a 3D CT-Scanner Using a Cone Beam and Video-Fluoroscopic System | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
遠藤, 真広
× 遠藤, 真広× 吉田, 勝哉× 日下部, 正宏× 舘野, 之男× その他× 遠藤 真広× 吉田 勝哉× 日下部 正宏× 舘野 之男 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We describe the design and implementation of a system that acquires three-dimensional (3D) data of high-contrast objects such as bone, lung, and blood vessels (enhanced by contrast agent). This 3D computed tomography (CT) system is based on a cone beam and video-fluoroscopic system and yields data that is amenable to 3D image processing. An X-ray tube and a large area two-dimensional detector were mounted on a single frame and rotated around objects in 12 seconds. The large area detector consisted of a fluorescent plate and a charge coupled device (CCD) video camera. While tha X-ray tube was rotated around the object, a pulsed X-ray was generated (30 pulses per second) and 360 projected images were collected in a 12-second scan. A 256x256x256 matrix image was reconstructed using a high-speed parallel processor. Reconstruction required approximately 6 minutes. Two volunteers under-went scans of the head or chest. High-contrast objects such as bronchial, vascular, and mediastinal structures in the thorax, or bones ans air cavities in the head were delineated in a "real" 3D format. Our 3D CT-scanner appears to produce data useful for clinical imaging and 3D image processing. | |||||
書誌情報 |
Radiation Medicine 巻 16, 号 1, p. 7-12, 発行日 1998 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0288-2043 |