WEKO3
アイテム
{"_buckets": {"deposit": "07f27cc6-825e-408a-aea7-eb75c992a2ca"}, "_deposit": {"created_by": 1, "id": "44337", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44337"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044337", "sets": ["1"]}, "author_link": ["440420", "440421", "440419", "440422", "440425", "440423", "440418", "440424"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "2541", "bibliographicPageStart": "2536", "bibliographicVolumeNumber": "26", "bibliographic_titles": [{"bibliographic_title": "American Journal of Neuroradiology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We report a preliminary demonstration of volumetric perfusion CT of the brain in domestic pigs using a prototype 256-detector row CT. Scan range is approximately 100 mm in the cranio-caudal direction with a slice thickness of 0.5 mm. The 256-detector row CT is a potentially easily available imaging modality that simultaneously provides volumetric cine imaging, CTA and perfusion CT with wide cranio-caudal coverage.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0195-6108", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mori, Shinichiro"}], "nameIdentifiers": [{"nameIdentifier": "440418", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Obata, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "440419", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Naoshi, Nakajima"}], "nameIdentifiers": [{"nameIdentifier": "440420", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ichihara, Nobutsune"}], "nameIdentifiers": [{"nameIdentifier": "440421", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Endo, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "440422", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440423", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小畠 隆行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440424", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "遠藤 真広", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440425", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Volumetric perfusion CT using prototype 256-detector row CT scanner: Preliminary study with healthy porcine model", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Volumetric perfusion CT using prototype 256-detector row CT scanner: Preliminary study with healthy porcine model"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44337", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-06-24"}, "publish_date": "2006-06-24", "publish_status": "0", "recid": "44337", "relation": {}, "relation_version_is_last": true, "title": ["Volumetric perfusion CT using prototype 256-detector row CT scanner: Preliminary study with healthy porcine model"], "weko_shared_id": -1}
Volumetric perfusion CT using prototype 256-detector row CT scanner: Preliminary study with healthy porcine model
https://repo.qst.go.jp/records/44337
https://repo.qst.go.jp/records/44337d64ccdba-13a3-441c-8514-a994b305d9cf
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-06-24 | |||||
タイトル | ||||||
タイトル | Volumetric perfusion CT using prototype 256-detector row CT scanner: Preliminary study with healthy porcine model | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mori, Shinichiro
× Mori, Shinichiro× Obata, Takayuki× Naoshi, Nakajima× Ichihara, Nobutsune× Endo, Masahiro× 森 慎一郎× 小畠 隆行× 遠藤 真広 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We report a preliminary demonstration of volumetric perfusion CT of the brain in domestic pigs using a prototype 256-detector row CT. Scan range is approximately 100 mm in the cranio-caudal direction with a slice thickness of 0.5 mm. The 256-detector row CT is a potentially easily available imaging modality that simultaneously provides volumetric cine imaging, CTA and perfusion CT with wide cranio-caudal coverage. | |||||
書誌情報 |
American Journal of Neuroradiology 巻 26, 号 10, p. 2536-2541, 発行日 2005-11 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0195-6108 |