WEKO3
アイテム
{"_buckets": {"deposit": "6b0e687e-76bb-49a5-91d0-d30266b6615f"}, "_deposit": {"created_by": 1, "id": "44317", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44317"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044317", "sets": ["1"]}, "author_link": ["440196", "440198", "440202", "440201", "440203", "440206", "440200", "440204", "440207", "440197", "440205", "440199"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1998", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "122", "bibliographicPageStart": "119", "bibliographicVolumeNumber": "5", "bibliographic_titles": [{"bibliographic_title": "胸部CT検診"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "被曝線量を大きく左右する因子として付加フィルタの有無や厚み、そして焦点−回転中心間距離の違いに着目し、当院で使用している3機種のCT装置において線質の比較を行った。半価層や実効エネルギーの違いは付加フィルタの有無や厚みおよび焦点ー回転中心間距離の差により明瞭となった。X線スペクトルでは低エネルギー領域において付加フィルタの有無や厚みの差がよく現れた。CTDIや胸部CT検診時の被曝線量は線質や焦点−回転中心間距離の違いで約1.3-1.7倍の差となった。", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1341-8556", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "岡本, 英明"}], "nameIdentifiers": [{"nameIdentifier": "440196", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木, 敬一"}], "nameIdentifiers": [{"nameIdentifier": "440197", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上田, 講記"}], "nameIdentifiers": [{"nameIdentifier": "440198", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "黒田, 知純"}], "nameIdentifiers": [{"nameIdentifier": "440199", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木, 隆一郎"}], "nameIdentifiers": [{"nameIdentifier": "440200", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 政雄"}], "nameIdentifiers": [{"nameIdentifier": "440201", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 徹"}], "nameIdentifiers": [{"nameIdentifier": "440202", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮本, 忠昭"}], "nameIdentifiers": [{"nameIdentifier": "440203", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "その他"}], "nameIdentifiers": [{"nameIdentifier": "440204", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 政雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440205", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 徹", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440206", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮本 忠昭", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440207", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "CT装置の線質、被曝線量の検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "CT装置の線質、被曝線量の検討"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44317", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-06-22"}, "publish_date": "2006-06-22", "publish_status": "0", "recid": "44317", "relation": {}, "relation_version_is_last": true, "title": ["CT装置の線質、被曝線量の検討"], "weko_shared_id": -1}
CT装置の線質、被曝線量の検討
https://repo.qst.go.jp/records/44317
https://repo.qst.go.jp/records/443179a328b57-b8c5-4d80-a4e1-8482ada78806
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-06-22 | |||||
タイトル | ||||||
タイトル | CT装置の線質、被曝線量の検討 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
岡本, 英明
× 岡本, 英明× 鈴木, 敬一× 上田, 講記× 黒田, 知純× 鈴木, 隆一郎× 松本, 政雄× 松本, 徹× 宮本, 忠昭× その他× 松本 政雄× 松本 徹× 宮本 忠昭 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 被曝線量を大きく左右する因子として付加フィルタの有無や厚み、そして焦点−回転中心間距離の違いに着目し、当院で使用している3機種のCT装置において線質の比較を行った。半価層や実効エネルギーの違いは付加フィルタの有無や厚みおよび焦点ー回転中心間距離の差により明瞭となった。X線スペクトルでは低エネルギー領域において付加フィルタの有無や厚みの差がよく現れた。CTDIや胸部CT検診時の被曝線量は線質や焦点−回転中心間距離の違いで約1.3-1.7倍の差となった。 | |||||
書誌情報 |
胸部CT検診 巻 5, 号 2, p. 119-122, 発行日 1998 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1341-8556 |