{"_buckets": {"deposit": "2cdc1f00-8730-4831-935d-c2c894abfa10"}, "_deposit": {"created_by": 1, "id": "44114", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44114"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044114", "sets": ["1"]}, "author_link": ["438498", "438497", "438503", "438501", "438502", "438496", "438500", "438494", "438504", "438495", "438499"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2000-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "115", "bibliographicPageStart": "112", "bibliographicVolumeNumber": "7", "bibliographic_titles": [{"bibliographic_title": "胸部CT検診"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "CT検診条件下の撮影において、CT装置やその他要因の違いがCT値にどの様な影響を及ぼすのか、試作ファントムを用いて検討した。水、GGOを呈する小型肺腺癌の球形模擬腫瘍4タイブ、肺野を壊したコルク片、空気のCT値を、装置間、mAs値、再構成関数、被曝低減フィルタの有無で比較した。結果、CT値は同一装置においてmAs値、再構成関数の違いによる大きなCT値の差はなかったが、CT装置の違いによる差は明確であった。また、被曝低減フィルタの有無によるCT値の差も認められた。", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1341-8556", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "米田, 晃敏"}], "nameIdentifiers": [{"nameIdentifier": "438494", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡本, 英明"}], "nameIdentifiers": [{"nameIdentifier": "438495", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂本, 正利"}], "nameIdentifiers": [{"nameIdentifier": "438496", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮崎, 正義"}], "nameIdentifiers": [{"nameIdentifier": "438497", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "黒田, 知純"}], "nameIdentifiers": [{"nameIdentifier": "438498", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木, 隆一郎"}], "nameIdentifiers": [{"nameIdentifier": "438499", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 徹"}], "nameIdentifiers": [{"nameIdentifier": "438500", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮本, 忠昭"}], "nameIdentifiers": [{"nameIdentifier": "438501", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "その他"}], "nameIdentifiers": [{"nameIdentifier": "438502", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 徹", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "438503", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮本 忠昭", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "438504", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "CT検診条件におけるCT装置の特性比較", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "CT検診条件におけるCT装置の特性比較"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44114", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-05-30"}, "publish_date": "2006-05-30", "publish_status": "0", "recid": "44114", "relation": {}, "relation_version_is_last": true, "title": ["CT検診条件におけるCT装置の特性比較"], "weko_shared_id": -1}
CT検診条件におけるCT装置の特性比較
https://repo.qst.go.jp/records/44114
https://repo.qst.go.jp/records/4411417a976d8-8080-474d-8496-929087afba23
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-05-30 | |||||
タイトル | ||||||
タイトル | CT検診条件におけるCT装置の特性比較 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
米田, 晃敏
× 米田, 晃敏× 岡本, 英明× 坂本, 正利× 宮崎, 正義× 黒田, 知純× 鈴木, 隆一郎× 松本, 徹× 宮本, 忠昭× その他× 松本 徹× 宮本 忠昭 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | CT検診条件下の撮影において、CT装置やその他要因の違いがCT値にどの様な影響を及ぼすのか、試作ファントムを用いて検討した。水、GGOを呈する小型肺腺癌の球形模擬腫瘍4タイブ、肺野を壊したコルク片、空気のCT値を、装置間、mAs値、再構成関数、被曝低減フィルタの有無で比較した。結果、CT値は同一装置においてmAs値、再構成関数の違いによる大きなCT値の差はなかったが、CT装置の違いによる差は明確であった。また、被曝低減フィルタの有無によるCT値の差も認められた。 | |||||
書誌情報 |
胸部CT検診 巻 7, 号 2, p. 112-115, 発行日 2000-08 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1341-8556 |