WEKO3
アイテム
{"_buckets": {"deposit": "ce903a27-5cc0-444d-bc45-be55574dd6c8"}, "_deposit": {"created_by": 1, "id": "43659", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "43659"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00043659", "sets": ["1"]}, "author_link": ["434097", "434096", "434099", "434093", "434098", "434100", "434095", "434094"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "1157", "bibliographicPageStart": "1153", "bibliographicVolumeNumber": "31", "bibliographic_titles": [{"bibliographic_title": "Medical Physics"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The goal of radiotherapy is not only to apply a high radiation dose to a tumor, but also to avoid side effects in the surrounding healthy tissue. Therefore, it is important for carbon-ion treatment planning to calculate accurately the effects of the lateral penumbra. In this article, for wobbled beams under various irradiation conditions, we focus on the lateral penumbras at several aperture positions of one side leaf of the multileaf collimator. The penumbras predicted by an analytical penumbra calculation model were compared with the measured results. The results calculated by the model for various conditions agreed well with the experimental ones. In conclusion, we found that the analytical penumbra calculation model could predict accurately the measured results for wobbled beams and it was useful for carbon-ion treatment planning to apply the model.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0094-2405", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kohno, Ryosuke"}], "nameIdentifiers": [{"nameIdentifier": "434093", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanematsu, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "434094", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yusa, Ken"}], "nameIdentifiers": [{"nameIdentifier": "434095", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanai, Tatsuaki"}], "nameIdentifiers": [{"nameIdentifier": "434096", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "河野 良介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "434097", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "兼松 伸幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "434098", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "遊佐 顕", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "434099", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金井 達明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "434100", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Experimental evaluation of analytical penumbra calculation model for wobbled beams", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Experimental evaluation of analytical penumbra calculation model for wobbled beams"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/43659", "pubdate": {"attribute_name": "公開日", "attribute_value": "2005-05-12"}, "publish_date": "2005-05-12", "publish_status": "0", "recid": "43659", "relation": {}, "relation_version_is_last": true, "title": ["Experimental evaluation of analytical penumbra calculation model for wobbled beams"], "weko_shared_id": -1}
Experimental evaluation of analytical penumbra calculation model for wobbled beams
https://repo.qst.go.jp/records/43659
https://repo.qst.go.jp/records/43659a1a3936a-b5d6-4201-9f50-79835fb95231
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-05-12 | |||||
タイトル | ||||||
タイトル | Experimental evaluation of analytical penumbra calculation model for wobbled beams | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kohno, Ryosuke
× Kohno, Ryosuke× Kanematsu, Nobuyuki× Yusa, Ken× Kanai, Tatsuaki× 河野 良介× 兼松 伸幸× 遊佐 顕× 金井 達明 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The goal of radiotherapy is not only to apply a high radiation dose to a tumor, but also to avoid side effects in the surrounding healthy tissue. Therefore, it is important for carbon-ion treatment planning to calculate accurately the effects of the lateral penumbra. In this article, for wobbled beams under various irradiation conditions, we focus on the lateral penumbras at several aperture positions of one side leaf of the multileaf collimator. The penumbras predicted by an analytical penumbra calculation model were compared with the measured results. The results calculated by the model for various conditions agreed well with the experimental ones. In conclusion, we found that the analytical penumbra calculation model could predict accurately the measured results for wobbled beams and it was useful for carbon-ion treatment planning to apply the model. | |||||
書誌情報 |
Medical Physics 巻 31, 号 5, p. 1153-1157, 発行日 2004-05 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0094-2405 |