WEKO3
アイテム
{"_buckets": {"deposit": "e5b8e0fa-487b-4f1c-b648-5c5a2d50c099"}, "_deposit": {"created_by": 1, "id": "43489", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "43489"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00043489", "sets": ["1"]}, "author_link": ["432483", "432481", "432482", "432479", "432485", "432484", "432486", "432480"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "9A", "bibliographicPageEnd": "6467", "bibliographicPageStart": "6463", "bibliographicVolumeNumber": "43", "bibliographic_titles": [{"bibliographic_title": "Japanese Journal of Applied Physics"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We propose an amplitude modulation wobbler-scatterer system, a so-called spiral-wobbler system, to produce a large irradiation field in a relatively short irradiation port for heavy-ion radiation therapy. The wobbler parameters, such as the wobbler-radius-modulation function, the wobbler radial frequency and the rotational frequency, are optimized and the uniformity of the irradiation field is estimated as the function of irradiation time. By using a wobbler radial frequency of 23 Hz, and a wobbler rotational frequency of 59 Hz, an irradiation field with a uniformity of +-3% can be obtained for an irradiation duration of 1 s. The spiral-wobbler system is applicable to respiration-gated irradiation.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0021-4922", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Komori, Masataka"}], "nameIdentifiers": [{"nameIdentifier": "432479", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furukawa, Takuji"}], "nameIdentifiers": [{"nameIdentifier": "432480", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanai, Tatsuaki"}], "nameIdentifiers": [{"nameIdentifier": "432481", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Noda, Kouji"}], "nameIdentifiers": [{"nameIdentifier": "432482", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小森 雅孝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "432483", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 卓司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "432484", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金井 達明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "432485", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "432486", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Optimization of Spiral-Wobbler System for Heavy-Ion Radiotherapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Optimization of Spiral-Wobbler System for Heavy-Ion Radiotherapy"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/43489", "pubdate": {"attribute_name": "公開日", "attribute_value": "2004-10-04"}, "publish_date": "2004-10-04", "publish_status": "0", "recid": "43489", "relation": {}, "relation_version_is_last": true, "title": ["Optimization of Spiral-Wobbler System for Heavy-Ion Radiotherapy"], "weko_shared_id": -1}
Optimization of Spiral-Wobbler System for Heavy-Ion Radiotherapy
https://repo.qst.go.jp/records/43489
https://repo.qst.go.jp/records/4348907f8c5db-a440-45fd-bcd9-bea8db1015d5
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2004-10-04 | |||||
タイトル | ||||||
タイトル | Optimization of Spiral-Wobbler System for Heavy-Ion Radiotherapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Komori, Masataka
× Komori, Masataka× Furukawa, Takuji× Kanai, Tatsuaki× Noda, Kouji× 小森 雅孝× 古川 卓司× 金井 達明× 野田 耕司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We propose an amplitude modulation wobbler-scatterer system, a so-called spiral-wobbler system, to produce a large irradiation field in a relatively short irradiation port for heavy-ion radiation therapy. The wobbler parameters, such as the wobbler-radius-modulation function, the wobbler radial frequency and the rotational frequency, are optimized and the uniformity of the irradiation field is estimated as the function of irradiation time. By using a wobbler radial frequency of 23 Hz, and a wobbler rotational frequency of 59 Hz, an irradiation field with a uniformity of +-3% can be obtained for an irradiation duration of 1 s. The spiral-wobbler system is applicable to respiration-gated irradiation. | |||||