{"_buckets": {"deposit": "2bfb5423-1744-4242-b452-7623f66bd985"}, "_deposit": {"created_by": 1, "id": "43449", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "43449"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00043449", "sets": ["1"]}, "author_link": ["432130", "432131", "432133", "432132", "432129"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-06", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "105", "bibliographicPageStart": "99", "bibliographicVolumeNumber": "36", "bibliographic_titles": [{"bibliographic_title": "Aquatic Microbial Ecology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A rapid fluorometric assay using the fluorescent dye SYBR Green I was established to\ndetermine the concentration of dissolved nucleic acids in fresh water. The ensitivity of SYBR Green I to double stranded DNA (dsDNA) (lambda Hind lll digest) was as low as 50 pg, 200 times more sensitive than Hoechst 33258. SYBR Green I bound to dsDNA emitted 10 times stronger fluorescence than when bound to single stranded DNA or RNA,indicating its selectivity for dsDNA measurement. The dissolved DNA (dDNA) concentration in fresh water determined using SYBR Green I was almost the same as that obtained using Hoechst 33258. This suggests that the dDNA measured by SYBR Green\nI is comparable to that determined by Hoechst 33258 in previous studies. To reduce preparation time,the dDNA in lake water filtrate was precipitated by ethanol and purified using a centrifugal filter device. The overall preparation process takes only a few hours and requires only 10 ml of water. The process described here may, therefore, facilitate \u0027same day\u0027measurement of dDNA dynamics in freshwater environments.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0948-3055", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kazuaki, Matsui"}], "nameIdentifiers": [{"nameIdentifier": "432129", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishii, Nobuyoshi"}], "nameIdentifiers": [{"nameIdentifier": "432130", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Honjo, Mie"}], "nameIdentifiers": [{"nameIdentifier": "432131", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawabata, Zenichiro"}], "nameIdentifiers": [{"nameIdentifier": "432132", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石井 伸昌", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "432133", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Use of the SYBR Green I fluorescent dye and a centrifugal filter device for rapid determination of dissolved DNA concentration in fresh water", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Use of the SYBR Green I fluorescent dye and a centrifugal filter device for rapid determination of dissolved DNA concentration in fresh water"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/43449", "pubdate": {"attribute_name": "公開日", "attribute_value": "2004-07-23"}, "publish_date": "2004-07-23", "publish_status": "0", "recid": "43449", "relation": {}, "relation_version_is_last": true, "title": ["Use of the SYBR Green I fluorescent dye and a centrifugal filter device for rapid determination of dissolved DNA concentration in fresh water"], "weko_shared_id": -1}
Use of the SYBR Green I fluorescent dye and a centrifugal filter device for rapid determination of dissolved DNA concentration in fresh water
https://repo.qst.go.jp/records/43449
https://repo.qst.go.jp/records/43449596b66d2-c147-41c4-870a-f81d2e832a7c
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2004-07-23 | |||||
タイトル | ||||||
タイトル | Use of the SYBR Green I fluorescent dye and a centrifugal filter device for rapid determination of dissolved DNA concentration in fresh water | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kazuaki, Matsui
× Kazuaki, Matsui× Ishii, Nobuyoshi× Honjo, Mie× Kawabata, Zenichiro× 石井 伸昌 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A rapid fluorometric assay using the fluorescent dye SYBR Green I was established to determine the concentration of dissolved nucleic acids in fresh water. The ensitivity of SYBR Green I to double stranded DNA (dsDNA) (lambda Hind lll digest) was as low as 50 pg, 200 times more sensitive than Hoechst 33258. SYBR Green I bound to dsDNA emitted 10 times stronger fluorescence than when bound to single stranded DNA or RNA,indicating its selectivity for dsDNA measurement. The dissolved DNA (dDNA) concentration in fresh water determined using SYBR Green I was almost the same as that obtained using Hoechst 33258. This suggests that the dDNA measured by SYBR Green I is comparable to that determined by Hoechst 33258 in previous studies. To reduce preparation time,the dDNA in lake water filtrate was precipitated by ethanol and purified using a centrifugal filter device. The overall preparation process takes only a few hours and requires only 10 ml of water. The process described here may, therefore, facilitate 'same day'measurement of dDNA dynamics in freshwater environments. |
|||||