量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
Conversion coefficients from ambient dose equivalent to effective doses of various age groups in areas affected by the 2011 Fukushima nuclear disaster
利用統計を見る
In case of nuclear accidents, it is important to determine the magnitude of radiation doses received by people living in contaminated territories. Direct measurement of individual external doses using personal dosimeters (PDs) worn by subjects is the most reliable solution for this necessity. However, it is not practical to expect that all returnees to the affected areas wear PDs. Thus, conversion factors from the ambient dose equivalent (ADEs) to the effective dose for various aged individuals must be determined appropriately. Previous studies demonstrated that the ratio of PDs to ADEs at various areas of Fukushima Prefecture mostly existed in the range of 0.6-0.7 [e.g.,1-3]. These studies provided evidence that PD readings would be reasonable estimators for the effective doses of adult subjects at locations where radioactive cesium is widely and uniformly deposited on the ground. In the present study, we experimentally obtained the response of PDs (D-shuttle, Chiyoda Technol., Tokyo, Japan; Dose i, Fuji Electric, Tokyo, Japan) attached to the front of five age-specific anthropometric phantoms (newborn, 1 y, 5y, 10y and adult male) for lateral radiations of 137Cs with various rotational angles. The PD/ADE ratio for the D-shuttle on the five phantoms with rotational irradiation simulating the exposure in Fukushima Prefecture were 0.87, 0.85, 0.83, 0.83 and 0.77, respectively. The ratio for newborns was 11 % higher than that for adult males. This body size dependency can be explained by the PD response to exposure direction. We discussed the results of this study and our field experiments to construct conversion coefficients from the ADE to the effective doses for age-group residents living in affected areas, which will be presented at the conference.
会議概要(会議名, 開催地, 会期, 主催者等)
International Conference on Individual Monitoring of Ionising Radiation (IM2022) and Neutron and Ion Dosimetry Symposium (NEUDOS-14)