WEKO3
アイテム
{"_buckets": {"deposit": "4cef3b8d-b46f-4fde-ad42-839ba8519848"}, "_deposit": {"created_by": 1, "id": "86385", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "86385"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00086385", "sets": ["1"]}, "author_link": ["1053588", "1053573", "1053574", "1053580", "1053585", "1053572", "1053577", "1053587", "1053575", "1053578", "1053579", "1053584", "1053589", "1053576", "1053583", "1053582", "1053586", "1053581"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2022-06", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{"bibliographic_title": "Head \u0026 neck"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Background: Chordoma is a rare, locally invasive neoplasm of the axial skeleton. Complete resection is often difficult, especially for the upper-cervical (C1-2) spine. We evaluated the efficacy and safety of carbon-ion radiotherapy (CIRT) for unresectable C1-2 chordoma.\nMethods: Patients with C1-2 chordoma treated with definitive CIRT (60.8 Gy [RBE] in 16 fractions) were retrospectively analyzed. We evaluated OS, LC, PFS, and toxicity.\nResults: Nineteen eligible patients all completed the planned course of CIRT. With the median follow-up 68 months (range: 29-144), median OS was 126 months (range: 36-NA). Five-year OS, LC, and PFS were 68.4% (95% CI, 42.8%-84.4%), 75.2% (46.1%-90.0%), and 64.1% (36.3%-82.3%), respectively. Regarding acute toxicity of grade ≥3, there was only one grade 3 mucositis. Late toxicity included radiation-induced myelitis (grade 3 in 1 patient; 5.3%), and compression fractures (n = 5; 26.3%).\nConclusions: High-dose CIRT is a promising treatment option for unresectable upper cervical chordoma.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "John Wiley And Sons"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "35734902", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1002/hed.27127", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1043-3074", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Aoki, Shuri"}], "nameIdentifiers": [{"nameIdentifier": "1053572", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koto, Masashi"}], "nameIdentifiers": [{"nameIdentifier": "1053573", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ikawa, Hiroaki"}], "nameIdentifiers": [{"nameIdentifier": "1053574", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Imai, Reiko"}], "nameIdentifiers": [{"nameIdentifier": "1053575", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tokuhiko, Omatsu"}], "nameIdentifiers": [{"nameIdentifier": "1053576", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shinoto, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "1053577", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takiyama, Hirotoshi"}], "nameIdentifiers": [{"nameIdentifier": "1053578", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Shigeru"}], "nameIdentifiers": [{"nameIdentifier": "1053579", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsuji, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "1053580", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shuri, Aoki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1053581", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Masashi, Koto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1053582", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hiroaki, Ikawa", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1053583", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Reiko, Imai", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1053584", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tokuhiko, Omatsu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1053585", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Makoto, Shinoto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1053586", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hirotoshi, Takiyama", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1053587", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shigeru, Yamada", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1053588", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hiroshi, Tsuji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1053589", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Long-term outcomes of high dose carbon-ion radiation therapy for unresectable upper cervical (C1-2) chordoma.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Long-term outcomes of high dose carbon-ion radiation therapy for unresectable upper cervical (C1-2) chordoma."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/86385", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-06-27"}, "publish_date": "2022-06-27", "publish_status": "0", "recid": "86385", "relation": {}, "relation_version_is_last": true, "title": ["Long-term outcomes of high dose carbon-ion radiation therapy for unresectable upper cervical (C1-2) chordoma."], "weko_shared_id": -1}
Long-term outcomes of high dose carbon-ion radiation therapy for unresectable upper cervical (C1-2) chordoma.
https://repo.qst.go.jp/records/86385
https://repo.qst.go.jp/records/86385a3376ef8-7cf3-4e6c-8ad5-b0cc042b50cf
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-06-27 | |||||
タイトル | ||||||
タイトル | Long-term outcomes of high dose carbon-ion radiation therapy for unresectable upper cervical (C1-2) chordoma. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Aoki, Shuri
× Aoki, Shuri× Koto, Masashi× Ikawa, Hiroaki× Imai, Reiko× Tokuhiko, Omatsu× Shinoto, Makoto× Takiyama, Hirotoshi× Yamada, Shigeru× Tsuji, Hiroshi× Shuri, Aoki× Masashi, Koto× Hiroaki, Ikawa× Reiko, Imai× Tokuhiko, Omatsu× Makoto, Shinoto× Hirotoshi, Takiyama× Shigeru, Yamada× Hiroshi, Tsuji |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Background: Chordoma is a rare, locally invasive neoplasm of the axial skeleton. Complete resection is often difficult, especially for the upper-cervical (C1-2) spine. We evaluated the efficacy and safety of carbon-ion radiotherapy (CIRT) for unresectable C1-2 chordoma. Methods: Patients with C1-2 chordoma treated with definitive CIRT (60.8 Gy [RBE] in 16 fractions) were retrospectively analyzed. We evaluated OS, LC, PFS, and toxicity. Results: Nineteen eligible patients all completed the planned course of CIRT. With the median follow-up 68 months (range: 29-144), median OS was 126 months (range: 36-NA). Five-year OS, LC, and PFS were 68.4% (95% CI, 42.8%-84.4%), 75.2% (46.1%-90.0%), and 64.1% (36.3%-82.3%), respectively. Regarding acute toxicity of grade ≥3, there was only one grade 3 mucositis. Late toxicity included radiation-induced myelitis (grade 3 in 1 patient; 5.3%), and compression fractures (n = 5; 26.3%). Conclusions: High-dose CIRT is a promising treatment option for unresectable upper cervical chordoma. |
|||||
書誌情報 |
Head & neck 発行日 2022-06 |
|||||
出版者 | ||||||
出版者 | John Wiley And Sons | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1043-3074 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 35734902 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1002/hed.27127 |