WEKO3
アイテム
{"_buckets": {"deposit": "ab906033-0a2c-4049-90c8-15570ddaec6f"}, "_deposit": {"created_by": 1, "id": "86090", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "86090"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00086090", "sets": ["11"]}, "author_link": ["1044853", "1044851", "1044852", "1044850"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2022-05", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{"bibliographic_title": "X-ray fluorescence in biological sciences"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "For rapid detection of uranium contamination in wounds at a nuclear fuel handling facility, a technique for XRF analysis of blood collected on small filter paper was developed, and a minimum detectable radioactivity of 0.31 mBq was obtained. This is much smaller than the lower detection limit of 1 Bq of the α-particle survey meter. This very simple and rapid technique has enabled the detection of uranium contamination in wounds with much higher sensitivity.", "subitem_description_type": "Abstract"}]}, "item_10004_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Wiley"}]}, "item_10004_relation_10": {"attribute_name": "ISBN", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "971119645542", "subitem_relation_type_select": "ISBN"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hiroshi, Yoshii"}], "nameIdentifiers": [{"nameIdentifier": "1044850", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yukie, Izumoto"}], "nameIdentifiers": [{"nameIdentifier": "1044851", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hiroshi, Yoshii", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1044852", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yukie, Izumoto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1044853", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "X-ray fluorescence in biological sciences", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "X-ray fluorescence in biological sciences"}]}, "item_type_id": "10004", "owner": "1", "path": ["11"], "permalink_uri": "https://repo.qst.go.jp/records/86090", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-05-10"}, "publish_date": "2022-05-10", "publish_status": "0", "recid": "86090", "relation": {}, "relation_version_is_last": true, "title": ["X-ray fluorescence in biological sciences"], "weko_shared_id": -1}
X-ray fluorescence in biological sciences
https://repo.qst.go.jp/records/86090
https://repo.qst.go.jp/records/86090f54d87b2-ca90-4928-9706-dffd447a082f
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-05-10 | |||||
タイトル | ||||||
タイトル | X-ray fluorescence in biological sciences | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hiroshi, Yoshii
× Hiroshi, Yoshii× Yukie, Izumoto× Hiroshi, Yoshii× Yukie, Izumoto |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | For rapid detection of uranium contamination in wounds at a nuclear fuel handling facility, a technique for XRF analysis of blood collected on small filter paper was developed, and a minimum detectable radioactivity of 0.31 mBq was obtained. This is much smaller than the lower detection limit of 1 Bq of the α-particle survey meter. This very simple and rapid technique has enabled the detection of uranium contamination in wounds with much higher sensitivity. | |||||
書誌情報 |
X-ray fluorescence in biological sciences 発行日 2022-05 |
|||||
出版者 | ||||||
出版者 | Wiley | |||||
ISBN | ||||||
識別子タイプ | ISBN | |||||
関連識別子 | 971119645542 |