{"_buckets": {"deposit": "55bd97a3-cf35-41e3-a3af-1f5fca0d5579"}, "_deposit": {"created_by": 1, "id": "85829", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "85829"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00085829", "sets": ["7"]}, "author_link": ["1034345", "1034344", "1034343", "1034342"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2022-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "123", "bibliographicPageStart": "123", "bibliographicVolumeNumber": "2021-8", "bibliographic_titles": [{"bibliographic_title": "KEK progress Report 2021-8: Photon Factory 2020年度年報"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "高エネルギー加速器研究機構・放射光実験室(フォトンファクトリー)のBL27Bは、非密封放射性同位元素を含む試料の吸収や蛍光X線のXAFS測定及びマイクロビーム照射ができる唯一のビームラインである。本ビームラインは、ユーザーグループ(放射線生物UG及び原子力基盤研究UG)が施設者と一体となって運用を実施してる。本稿では、2020年度の運用実績及び今後の展望が示されている。", "subitem_description_type": "Abstract"}]}, "item_10004_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "chrome-extension://efaidnbmnnnibpcajpcglclefindmkaj/viewer.html?pdfurl=https%3A%2F%2Fwww2.kek.jp%2Fimss%2Fpf%2Fscience%2Fpubl%2Fpfnenpo%2F2020%2F5_BL.pdf\u0026clen=8655237\u0026chunk=true", "subitem_relation_type_select": "URI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "宇佐美, 徳子"}], "nameIdentifiers": [{"nameIdentifier": "1034342", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "横谷, 明徳"}], "nameIdentifiers": [{"nameIdentifier": "1034343", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡本, 芳浩"}], "nameIdentifiers": [{"nameIdentifier": "1034344", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akinari, Yokoya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1034345", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "BL27B: 放射性試料用X線実験ステーション", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "BL27B: 放射性試料用X線実験ステーション"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/85829", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-03-18"}, "publish_date": "2022-03-18", "publish_status": "0", "recid": "85829", "relation": {}, "relation_version_is_last": true, "title": ["BL27B: 放射性試料用X線実験ステーション"], "weko_shared_id": -1}
BL27B: 放射性試料用X線実験ステーション
https://repo.qst.go.jp/records/85829
https://repo.qst.go.jp/records/85829a9a9327c-0f11-4f5b-ad0f-75efe857a209
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-03-18 | |||||
タイトル | ||||||
タイトル | BL27B: 放射性試料用X線実験ステーション | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
宇佐美, 徳子
× 宇佐美, 徳子× 横谷, 明徳× 岡本, 芳浩× Akinari, Yokoya |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 高エネルギー加速器研究機構・放射光実験室(フォトンファクトリー)のBL27Bは、非密封放射性同位元素を含む試料の吸収や蛍光X線のXAFS測定及びマイクロビーム照射ができる唯一のビームラインである。本ビームラインは、ユーザーグループ(放射線生物UG及び原子力基盤研究UG)が施設者と一体となって運用を実施してる。本稿では、2020年度の運用実績及び今後の展望が示されている。 | |||||
書誌情報 |
KEK progress Report 2021-8: Photon Factory 2020年度年報 巻 2021-8, p. 123-123, 発行日 2022-03 |
|||||