WEKO3
アイテム
{"_buckets": {"deposit": "0e2c0cfb-5af6-48cd-8ff9-901ab3a12144"}, "_deposit": {"created_by": 1, "id": "78413", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "78413"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00078413", "sets": ["2"]}, "author_link": ["902342", "902349", "902343", "902348", "902350", "902351", "902345", "902347", "902353", "902355", "902346", "902344", "902352", "902354"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-11", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "1284", "bibliographicPageStart": "1282", "bibliographic_titles": [{"bibliographic_title": "2019年第16回日本加速器学会年会プロシーディング"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The cyclotron facility at National Institute of Radiological Sciences (NIRS) consists of a NIRS-930 cyclotron (Thomson-CSF AVF-930, Kb=110 MeV and Kf=90 MeV) and a small cyclotron HM-18(Sumitomo- Heavy- Industry HM-18, K=20 MeV). The NIRS-930 has been used for production of radionuclide. The other purposes of NIRS-930 were research of physics, developments of particle detectors in space, research of biology, and so on. The annual total operation time of NIRS-930 in last year was 1731 hours. The HM-18, that is a fixed energy negative-ion accelerator, has been providing 18 MeV protons and 9 MeV deuterons in order to produce short-lived radio-pharmaceuticals for Positron Emission Tomography (PET). The annual total operation time of HM-18 in last year was 1686 hours.\n", "subitem_description_type": "Abstract"}]}, "item_10003_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.pasj.jp/web_publish/pasj2019/proceedings/PDF/FSPI/FSPI017.pdf", "subitem_relation_type_select": "URI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "北條, 悟"}], "nameIdentifiers": [{"nameIdentifier": "902342", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "涌井, 崇志"}], "nameIdentifiers": [{"nameIdentifier": "902343", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "片桐, 健"}], "nameIdentifiers": [{"nameIdentifier": "902344", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "杉浦, 彰則"}], "nameIdentifiers": [{"nameIdentifier": "902345", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原, 信幸"}], "nameIdentifiers": [{"nameIdentifier": "902346", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡田, 高典(AEC)"}], "nameIdentifiers": [{"nameIdentifier": "902347", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "立川, 裕士(AEC)"}], "nameIdentifiers": [{"nameIdentifier": "902348", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白井, 敏之"}], "nameIdentifiers": [{"nameIdentifier": "902349", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hojo, Satoru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "902350", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wakui, Takashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "902351", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Katagiri, Ken", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "902352", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sugiura, Akinori", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "902353", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miyahara, Nobuyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "902354", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shirai, Toshiyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "902355", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "放医研サイクロトロン(NIRS-930, HM-18)の現状報告 2019", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "放医研サイクロトロン(NIRS-930, HM-18)の現状報告 2019"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/78413", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-11-26"}, "publish_date": "2019-11-26", "publish_status": "0", "recid": "78413", "relation": {}, "relation_version_is_last": true, "title": ["放医研サイクロトロン(NIRS-930, HM-18)の現状報告 2019"], "weko_shared_id": -1}
放医研サイクロトロン(NIRS-930, HM-18)の現状報告 2019
https://repo.qst.go.jp/records/78413
https://repo.qst.go.jp/records/78413c1b0eb92-b985-4cb4-a682-5cd8e178269e
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-11-26 | |||||
タイトル | ||||||
タイトル | 放医研サイクロトロン(NIRS-930, HM-18)の現状報告 2019 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
北條, 悟
× 北條, 悟× 涌井, 崇志× 片桐, 健× 杉浦, 彰則× 宮原, 信幸× 岡田, 高典(AEC)× 立川, 裕士(AEC)× 白井, 敏之× Hojo, Satoru× Wakui, Takashi× Katagiri, Ken× Sugiura, Akinori× Miyahara, Nobuyuki× Shirai, Toshiyuki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The cyclotron facility at National Institute of Radiological Sciences (NIRS) consists of a NIRS-930 cyclotron (Thomson-CSF AVF-930, Kb=110 MeV and Kf=90 MeV) and a small cyclotron HM-18(Sumitomo- Heavy- Industry HM-18, K=20 MeV). The NIRS-930 has been used for production of radionuclide. The other purposes of NIRS-930 were research of physics, developments of particle detectors in space, research of biology, and so on. The annual total operation time of NIRS-930 in last year was 1731 hours. The HM-18, that is a fixed energy negative-ion accelerator, has been providing 18 MeV protons and 9 MeV deuterons in order to produce short-lived radio-pharmaceuticals for Positron Emission Tomography (PET). The annual total operation time of HM-18 in last year was 1686 hours. | |||||
書誌情報 |
2019年第16回日本加速器学会年会プロシーディング p. 1282-1284, 発行日 2019-11 |
|||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.pasj.jp/web_publish/pasj2019/proceedings/PDF/FSPI/FSPI017.pdf |