WEKO3
アイテム
{"_buckets": {"deposit": "95312ef2-7296-4293-a89f-58d8a4a4b51b"}, "_deposit": {"created_by": 1, "id": "78412", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "78412"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00078412", "sets": ["2"]}, "author_link": ["860655", "860658", "860659", "860663", "860656", "860660", "860661", "860662", "860664", "860657"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-11", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "1143", "bibliographicPageStart": "1139", "bibliographic_titles": [{"bibliographic_title": "2019年第16回日本加速器学会年会プロシーディング"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "An isotope separation on-line (ISOL) system is necessary to provide 11C ions for heavy-ion cancer therapy with simultaneous verification of the dose distribution using positron emission tomography. To realize the ISOL system, we have developed elementary instruments in the ISOL system, such as a proton-irradiation target, a molecule separation system, and a singly-charged ion source, and performed tests to verify their performances. As a next step of the development, we started an experiment of on-line production of singly-charged 11C ions at the proton irradiation port of the NIRS-cyclotron facility. In this paper, we present the results and the status of the on-line production experiments.\n", "subitem_description_type": "Abstract"}]}, "item_10003_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.pasj.jp/web_publish/pasj2019/proceedings/PDF/FRPI/FRPI042.pdf", "subitem_relation_type_select": "URI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "片桐, 健"}], "nameIdentifiers": [{"nameIdentifier": "860655", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "涌井, 崇志"}], "nameIdentifiers": [{"nameIdentifier": "860656", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北條, 悟"}], "nameIdentifiers": [{"nameIdentifier": "860657", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田, 章"}], "nameIdentifiers": [{"nameIdentifier": "860658", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白井, 敏之"}], "nameIdentifiers": [{"nameIdentifier": "860659", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Katagiri, Ken", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "860660", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wakui, Takashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "860661", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hojo, Satoru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "860662", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Noda, Akira", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "860663", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shirai, Toshiyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "860664", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "RIビームがん治療の実現を目指した1 価C-11 イオン生成実験の状況", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "RIビームがん治療の実現を目指した1 価C-11 イオン生成実験の状況"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/78412", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-11-26"}, "publish_date": "2019-11-26", "publish_status": "0", "recid": "78412", "relation": {}, "relation_version_is_last": true, "title": ["RIビームがん治療の実現を目指した1 価C-11 イオン生成実験の状況"], "weko_shared_id": -1}
RIビームがん治療の実現を目指した1 価C-11 イオン生成実験の状況
https://repo.qst.go.jp/records/78412
https://repo.qst.go.jp/records/78412d0c29317-0867-4062-96c5-64815d67c13c
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-11-26 | |||||
タイトル | ||||||
タイトル | RIビームがん治療の実現を目指した1 価C-11 イオン生成実験の状況 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
片桐, 健
× 片桐, 健× 涌井, 崇志× 北條, 悟× 野田, 章× 白井, 敏之× Katagiri, Ken× Wakui, Takashi× Hojo, Satoru× Noda, Akira× Shirai, Toshiyuki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | An isotope separation on-line (ISOL) system is necessary to provide 11C ions for heavy-ion cancer therapy with simultaneous verification of the dose distribution using positron emission tomography. To realize the ISOL system, we have developed elementary instruments in the ISOL system, such as a proton-irradiation target, a molecule separation system, and a singly-charged ion source, and performed tests to verify their performances. As a next step of the development, we started an experiment of on-line production of singly-charged 11C ions at the proton irradiation port of the NIRS-cyclotron facility. In this paper, we present the results and the status of the on-line production experiments. | |||||
書誌情報 |
2019年第16回日本加速器学会年会プロシーディング p. 1139-1143, 発行日 2019-11 |
|||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.pasj.jp/web_publish/pasj2019/proceedings/PDF/FRPI/FRPI042.pdf |