{"_buckets": {"deposit": "d22f07d5-0aae-4dc8-9a4e-83182862f731"}, "_deposit": {"created_by": 1, "id": "78022", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "78022"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00078022", "sets": ["1"]}, "author_link": ["881377", "881379", "881382", "881373", "881378", "881372", "881384", "881380", "881376", "881383", "881370", "881385", "881368", "881381", "881369", "881371", "881374", "881375"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "281", "bibliographicPageStart": "276", "bibliographicVolumeNumber": "19", "bibliographic_titles": [{"bibliographic_title": "Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We investigated the usefulness of diffusion-weighted imaging (DWI) for detecting changes in the structure of hypoxic cells by evaluating the correlation between F-fluoroazomycin arabinoside (FAZA) positron emission tomography activity and DWI parameters in head and neck carcinoma. The diffusion coefficient corresponding to the slow compartment of a two-compartment model had a significant positive correlation with FAZA activity (ρ = 0.58, P = 0.016), whereas the diffusional kurtosis from diffusion kurtosis imaging had a significant negative correlation (ρ = -0.62, P = 0.008), which suggests that those DWI parameters might be useful as indicators for changes in cell structure.", "subitem_description_type": "Abstract"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "31548478", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.2463/mrms.tn.2019-0007", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/article/mrms/19/3/19_tn.2019-0007/_article", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1347-3182", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Imaizumi, Akiko"}], "nameIdentifiers": [{"nameIdentifier": "881368", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Obata, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "881369", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kershaw, Jeff"}], "nameIdentifiers": [{"nameIdentifier": "881370", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tachibana, Yasuhiko"}], "nameIdentifiers": [{"nameIdentifier": "881371", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inubushi, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "881372", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koizumi, Mitsuru"}], "nameIdentifiers": [{"nameIdentifier": "881373", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshikawa, Kyosan"}], "nameIdentifiers": [{"nameIdentifier": "881374", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ming-Rong, Zhang"}], "nameIdentifiers": [{"nameIdentifier": "881375", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanimoto, Katsuyuki"}], "nameIdentifiers": [{"nameIdentifier": "881376", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Harada, Rintaro"}], "nameIdentifiers": [{"nameIdentifier": "881377", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uno, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "881378", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Saga, Tsuneo"}], "nameIdentifiers": [{"nameIdentifier": "881379", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Imaizumi, Akiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "881380", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Obata, Takayuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "881381", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kershaw, Jeffrey", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "881382", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tachibana, Yasuhiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "881383", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ming-Rong, Zhang", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "881384", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanimoto, Katsuyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "881385", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Imaging of Hypoxic Tumor: Correlation between Diffusion-weighted MR Imaging and F-fluoroazomycin Arabinoside Positron Emission Tomography in Head and Neck Carcinoma.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Imaging of Hypoxic Tumor: Correlation between Diffusion-weighted MR Imaging and F-fluoroazomycin Arabinoside Positron Emission Tomography in Head and Neck Carcinoma."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/78022", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-12-17"}, "publish_date": "2019-12-17", "publish_status": "0", "recid": "78022", "relation": {}, "relation_version_is_last": true, "title": ["Imaging of Hypoxic Tumor: Correlation between Diffusion-weighted MR Imaging and F-fluoroazomycin Arabinoside Positron Emission Tomography in Head and Neck Carcinoma."], "weko_shared_id": -1}
Imaging of Hypoxic Tumor: Correlation between Diffusion-weighted MR Imaging and F-fluoroazomycin Arabinoside Positron Emission Tomography in Head and Neck Carcinoma.
https://repo.qst.go.jp/records/78022
https://repo.qst.go.jp/records/78022c9fc6696-120a-4d30-b747-3c60ce030f42
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-12-17 | |||||
タイトル | ||||||
タイトル | Imaging of Hypoxic Tumor: Correlation between Diffusion-weighted MR Imaging and F-fluoroazomycin Arabinoside Positron Emission Tomography in Head and Neck Carcinoma. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Imaizumi, Akiko
× Imaizumi, Akiko× Obata, Takayuki× Kershaw, Jeff× Tachibana, Yasuhiko× Inubushi, Masayuki× Koizumi, Mitsuru× Yoshikawa, Kyosan× Ming-Rong, Zhang× Tanimoto, Katsuyuki× Harada, Rintaro× Uno, Takashi× Saga, Tsuneo× Imaizumi, Akiko× Obata, Takayuki× Kershaw, Jeffrey× Tachibana, Yasuhiko× Ming-Rong, Zhang× Tanimoto, Katsuyuki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We investigated the usefulness of diffusion-weighted imaging (DWI) for detecting changes in the structure of hypoxic cells by evaluating the correlation between F-fluoroazomycin arabinoside (FAZA) positron emission tomography activity and DWI parameters in head and neck carcinoma. The diffusion coefficient corresponding to the slow compartment of a two-compartment model had a significant positive correlation with FAZA activity (ρ = 0.58, P = 0.016), whereas the diffusional kurtosis from diffusion kurtosis imaging had a significant negative correlation (ρ = -0.62, P = 0.008), which suggests that those DWI parameters might be useful as indicators for changes in cell structure. | |||||
書誌情報 |
Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine 巻 19, 号 3, p. 276-281, 発行日 2019-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1347-3182 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 31548478 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.2463/mrms.tn.2019-0007 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/article/mrms/19/3/19_tn.2019-0007/_article |