{"_buckets": {"deposit": "e2a1efab-d166-4a6c-a1a5-8535d709413e"}, "_deposit": {"created_by": 1, "id": "77588", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "77588"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00077588", "sets": ["1"]}, "author_link": ["999125", "999126", "999128", "999123", "999127", "999124"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "466", "bibliographicPageStart": "459", "bibliographicVolumeNumber": "54", "bibliographic_titles": [{"bibliographic_title": "低温工学"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "ITER TFコイルには総重量約5000トンの極低温構造材料が使用される。それらは4Kに冷却され、巨大な電磁力が掛かるため、高い引張特性(降伏応力)が要求される。オーステナイトステンレス鋼中のCとN量の和と室温降伏応力から4Kにおける降伏応力を予測する式があるが、その予測式を応用して要求降伏応力に対応する化学成分、室温降伏応力が規格化され、誤差の分だけマージンを持たせ実機仕様となった。筆者らは実機材料から抜き取りで4K引張試験を実施し、全数の成分分析及び室温における引張試験結果と合わせてそのデータを分析した。4Kにおける降伏応力とCとN量の和は良い相関を示した。しかしながら、予測値は実測値よりも11.2%程度高くなる傾向があり、原因は室温試験の試験速度と窒素の過飽和と考えられる。実機材料製造ではCとN量の下限を0.02上げたが、その効果により裕度を持って全材料は要求値を満たした。", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "公益社団法人 低温工学・超電導学会"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.2221/jcsj.54.459", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/article/jcsj/54/6/54_459/_article/-char/ja/", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0389-2441", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "櫻井, 武尊"}], "nameIdentifiers": [{"nameIdentifier": "999123", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "井口, 将秀"}], "nameIdentifiers": [{"nameIdentifier": "999124", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中平, 昌隆"}], "nameIdentifiers": [{"nameIdentifier": "999125", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takeru, Sakurai", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "999126", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Masahide, Iguchi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "999127", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Masataka, Nakahira", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "999128", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "ITER TFコイル用極低温構造材料の引張特性評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "ITER TFコイル用極低温構造材料の引張特性評価"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/77588", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-11-22"}, "publish_date": "2019-11-22", "publish_status": "0", "recid": "77588", "relation": {}, "relation_version_is_last": true, "title": ["ITER TFコイル用極低温構造材料の引張特性評価"], "weko_shared_id": -1}
ITER TFコイル用極低温構造材料の引張特性評価
https://repo.qst.go.jp/records/77588
https://repo.qst.go.jp/records/7758819b910b0-bf50-4fa6-92be-893ce091bfe2
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-11-22 | |||||
タイトル | ||||||
タイトル | ITER TFコイル用極低温構造材料の引張特性評価 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
櫻井, 武尊
× 櫻井, 武尊× 井口, 将秀× 中平, 昌隆× Takeru, Sakurai× Masahide, Iguchi× Masataka, Nakahira |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | ITER TFコイルには総重量約5000トンの極低温構造材料が使用される。それらは4Kに冷却され、巨大な電磁力が掛かるため、高い引張特性(降伏応力)が要求される。オーステナイトステンレス鋼中のCとN量の和と室温降伏応力から4Kにおける降伏応力を予測する式があるが、その予測式を応用して要求降伏応力に対応する化学成分、室温降伏応力が規格化され、誤差の分だけマージンを持たせ実機仕様となった。筆者らは実機材料から抜き取りで4K引張試験を実施し、全数の成分分析及び室温における引張試験結果と合わせてそのデータを分析した。4Kにおける降伏応力とCとN量の和は良い相関を示した。しかしながら、予測値は実測値よりも11.2%程度高くなる傾向があり、原因は室温試験の試験速度と窒素の過飽和と考えられる。実機材料製造ではCとN量の下限を0.02上げたが、その効果により裕度を持って全材料は要求値を満たした。 | |||||
書誌情報 |
低温工学 巻 54, 号 6, p. 459-466, 発行日 2019-11 |
|||||
出版者 | ||||||
出版者 | 公益社団法人 低温工学・超電導学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0389-2441 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.2221/jcsj.54.459 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/article/jcsj/54/6/54_459/_article/-char/ja/ |