{"_buckets": {"deposit": "11074e65-1f1c-4a6d-9fb7-29b934693651"}, "_deposit": {"created_by": 1, "id": "77292", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "77292"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00077292", "sets": ["28"]}, "author_link": ["797513", "797512", "797526", "797522", "797514", "797517", "797523", "797515", "797516", "797518", "797520", "797521", "797524", "797525", "797511", "797519"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2019-11-01", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Coronary artery disease (CAD) is one of the leading causes of death world-wide. Noninvasive quantification of myocardial blood flow with PET is a key tool for detection and monitoring of CAD. However, current standard cylindrical PET scanners are not optimized for cardiac imaging because they are designed mainly for whole-body imaging. In this study, we proposed two compact geometries, the elliptical geometry and the D-shape geometry, for a cardiac-dedicated PET system. We compared their performance with a conventional cylindrical geometry by using the Geant4 simulation toolkit. Furthermore, we evaluated two detector designs with different LYSO crystal thicknesses (20-mm and 10-mm) and appropriate practical coincidence timing resolutions (CTRs) (300 ps for 20 mm LYSO and 250 ps for 10 mm LYSO) to investigate a suitable detector design. In the simulation, an elliptical water phantom (10 MBq) was scanned for 10 s. We evaluated the sensitivity, the noise-equivalent count rate (NECR), and image noise (coefficient of variation: CV) of the water phantom. The D-shape geometry with the 20 mm long LYSO showed the highest sensitivity and NECR. This geometry achieved 71% higher sensitivity and 44% higher NECR compared with the conventional cylindrical geometry. The image noise (CV) was decreased by 24%. The number of detectors was reduced to 3/8 (37.5%). On the other hand, the system with the half-thickness crystal did not show any improvement in the image noise compared with the whole-body cylindrical geometry. With the 20 mm long LYSO, our proposed D-shape geometry is a promising design for a high-sensitivity cardiac-dedicated PET system.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Akamatsu, Go"}], "nameIdentifiers": [{"nameIdentifier": "797511", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashima, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "797512", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwao, Yuma"}], "nameIdentifiers": [{"nameIdentifier": "797513", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takyu, Sodai"}], "nameIdentifiers": [{"nameIdentifier": "797514", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kang, Hangyu"}], "nameIdentifiers": [{"nameIdentifier": "797515", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takahashi, Miwako"}], "nameIdentifiers": [{"nameIdentifier": "797516", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "797517", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "797518", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akamatsu, Go", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "797519", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashima, Hideaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "797520", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwao, Yuma", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "797521", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takyu, Sodai", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "797522", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kang, Hangyu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "797523", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takahashi, Miwako", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "797524", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Eiji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "797525", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "797526", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Design study of cardiac-dedicated TOF-PET systems with compact detector arrangement", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Design study of cardiac-dedicated TOF-PET systems with compact detector arrangement"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/77292", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-10-02"}, "publish_date": "2019-10-02", "publish_status": "0", "recid": "77292", "relation": {}, "relation_version_is_last": true, "title": ["Design study of cardiac-dedicated TOF-PET systems with compact detector arrangement"], "weko_shared_id": -1}
Design study of cardiac-dedicated TOF-PET systems with compact detector arrangement
https://repo.qst.go.jp/records/77292
https://repo.qst.go.jp/records/772920f5259a2-fb3b-4175-be1e-758777416322
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-10-02 | |||||
タイトル | ||||||
タイトル | Design study of cardiac-dedicated TOF-PET systems with compact detector arrangement | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Akamatsu, Go
× Akamatsu, Go× Tashima, Hideaki× Iwao, Yuma× Takyu, Sodai× Kang, Hangyu× Takahashi, Miwako× Yoshida, Eiji× Yamaya, Taiga× Akamatsu, Go× Tashima, Hideaki× Iwao, Yuma× Takyu, Sodai× Kang, Hangyu× Takahashi, Miwako× Yoshida, Eiji× Yamaya, Taiga |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Coronary artery disease (CAD) is one of the leading causes of death world-wide. Noninvasive quantification of myocardial blood flow with PET is a key tool for detection and monitoring of CAD. However, current standard cylindrical PET scanners are not optimized for cardiac imaging because they are designed mainly for whole-body imaging. In this study, we proposed two compact geometries, the elliptical geometry and the D-shape geometry, for a cardiac-dedicated PET system. We compared their performance with a conventional cylindrical geometry by using the Geant4 simulation toolkit. Furthermore, we evaluated two detector designs with different LYSO crystal thicknesses (20-mm and 10-mm) and appropriate practical coincidence timing resolutions (CTRs) (300 ps for 20 mm LYSO and 250 ps for 10 mm LYSO) to investigate a suitable detector design. In the simulation, an elliptical water phantom (10 MBq) was scanned for 10 s. We evaluated the sensitivity, the noise-equivalent count rate (NECR), and image noise (coefficient of variation: CV) of the water phantom. The D-shape geometry with the 20 mm long LYSO showed the highest sensitivity and NECR. This geometry achieved 71% higher sensitivity and 44% higher NECR compared with the conventional cylindrical geometry. The image noise (CV) was decreased by 24%. The number of detectors was reduced to 3/8 (37.5%). On the other hand, the system with the half-thickness crystal did not show any improvement in the image noise compared with the whole-body cylindrical geometry. With the 20 mm long LYSO, our proposed D-shape geometry is a promising design for a high-sensitivity cardiac-dedicated PET system. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) | |||||
発表年月日 | ||||||
日付 | 2019-11-01 | |||||
日付タイプ | Issued |