{"_buckets": {"deposit": "a92b6eb0-788f-4783-b7ad-a997d2003ce9"}, "_deposit": {"created_by": 1, "id": "76220", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "76220"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00076220", "sets": ["1"]}, "author_link": ["791016", "791018", "791019", "791020", "791017", "791021", "791015"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "13", "bibliographicPageEnd": "135019-15", "bibliographicPageStart": "135019-1", "bibliographicVolumeNumber": "64", "bibliographic_titles": [{"bibliographic_title": "Physics Medicine Biology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Low-energy X-ray imaging of the secondary electron bremsstrahlung X-ray emitted during carbon-ion irradiation is a promising method for range estimation. However, it remains unclear whether the method can be used for imaging with the clinical dose levels of carbon-ion and whether the bremsstrahlung X-ray can be detected from the deeper part of the body. To clarify these points, we developed a new high resolution low-energy X-ray camera and conducted imaging of the secondary electron bremsstrahlung X-ray during the irradiation of carbon-ions of different energies and intensities. Imaging was also tried with an X-ray camera using a human-head-sized, 17-cm diameter cylindrical phantom. To develop a high resolution imaging detector for a low-energy X-ray, we used a 20 × 20 × 0.5 mm thick cerium-doped yttrium aluminum perovskite, YA1O3 (YAP(Ce)) scintillator plate, which was optically coupled to a 25mm square high quantum efficiency (HQE) type position sensitive photomultiplier tube (PSPMT). The imaging detector was encased in a 2 cm thick tungsten container and a pinhole collimator was attached to its camera head. After evaluating the camera’s performance, secondary electron bremsstrahlung X-ray imaging was tried during irradiation of the carbon-ion and compared the results with a Monte Carlo simulation. We imaged the beam tracks by the secondary electron bremsstrahlung X-ray in real-time during irradiation of the carbon-ion and imaging and range estimation were possible even with near clinical dose level of 7.5 × 108 particles of carbon-ion. Clear images of a secondary electron bremsstrahlung X-ray were also obtained for a 17-cm diameter cylindrical phantom. The measured images were good agreement with the Monte Carlo simulation. We confirmed that our developed YAP(Ce) camera is promising for imaging secondary electron bremsstrahlung X-rays during irradiation of carbon-ions even near clinical conditions.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IOP Publishing"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1088/1361-6560/ab2072", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1088/1361-6560/ab2072", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0031-9155", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Seiichi, Yamamoto (Nagoya Univ.)"}], "nameIdentifiers": [{"nameIdentifier": "791015", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaguchi, Mitsutaka"}], "nameIdentifiers": [{"nameIdentifier": "791016", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takashi, Akagi (Hyogo Ion Beam Medical Center)"}], "nameIdentifiers": [{"nameIdentifier": "791017", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Makoto, Sasano (Mitsubishi Electric Corp.)"}], "nameIdentifiers": [{"nameIdentifier": "791018", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawachi, Naoki"}], "nameIdentifiers": [{"nameIdentifier": "791019", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaguchi, Mitsutaka", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "791020", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawachi, Naoki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "791021", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Development of a YAP(Ce) camera for the imaging of secondary electron bremsstrahlung X-ray emitted during carbon-ion irradiation toward the use of clinical conditions", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of a YAP(Ce) camera for the imaging of secondary electron bremsstrahlung X-ray emitted during carbon-ion irradiation toward the use of clinical conditions"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/76220", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-05-08"}, "publish_date": "2019-05-08", "publish_status": "0", "recid": "76220", "relation": {}, "relation_version_is_last": true, "title": ["Development of a YAP(Ce) camera for the imaging of secondary electron bremsstrahlung X-ray emitted during carbon-ion irradiation toward the use of clinical conditions"], "weko_shared_id": -1}
Development of a YAP(Ce) camera for the imaging of secondary electron bremsstrahlung X-ray emitted during carbon-ion irradiation toward the use of clinical conditions
https://repo.qst.go.jp/records/76220
https://repo.qst.go.jp/records/7622053c959fe-9498-443d-a3c0-eed0b800ce86
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-05-08 | |||||
タイトル | ||||||
タイトル | Development of a YAP(Ce) camera for the imaging of secondary electron bremsstrahlung X-ray emitted during carbon-ion irradiation toward the use of clinical conditions | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Seiichi, Yamamoto (Nagoya Univ.)
× Seiichi, Yamamoto (Nagoya Univ.)× Yamaguchi, Mitsutaka× Takashi, Akagi (Hyogo Ion Beam Medical Center)× Makoto, Sasano (Mitsubishi Electric Corp.)× Kawachi, Naoki× Yamaguchi, Mitsutaka× Kawachi, Naoki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Low-energy X-ray imaging of the secondary electron bremsstrahlung X-ray emitted during carbon-ion irradiation is a promising method for range estimation. However, it remains unclear whether the method can be used for imaging with the clinical dose levels of carbon-ion and whether the bremsstrahlung X-ray can be detected from the deeper part of the body. To clarify these points, we developed a new high resolution low-energy X-ray camera and conducted imaging of the secondary electron bremsstrahlung X-ray during the irradiation of carbon-ions of different energies and intensities. Imaging was also tried with an X-ray camera using a human-head-sized, 17-cm diameter cylindrical phantom. To develop a high resolution imaging detector for a low-energy X-ray, we used a 20 × 20 × 0.5 mm thick cerium-doped yttrium aluminum perovskite, YA1O3 (YAP(Ce)) scintillator plate, which was optically coupled to a 25mm square high quantum efficiency (HQE) type position sensitive photomultiplier tube (PSPMT). The imaging detector was encased in a 2 cm thick tungsten container and a pinhole collimator was attached to its camera head. After evaluating the camera’s performance, secondary electron bremsstrahlung X-ray imaging was tried during irradiation of the carbon-ion and compared the results with a Monte Carlo simulation. We imaged the beam tracks by the secondary electron bremsstrahlung X-ray in real-time during irradiation of the carbon-ion and imaging and range estimation were possible even with near clinical dose level of 7.5 × 108 particles of carbon-ion. Clear images of a secondary electron bremsstrahlung X-ray were also obtained for a 17-cm diameter cylindrical phantom. The measured images were good agreement with the Monte Carlo simulation. We confirmed that our developed YAP(Ce) camera is promising for imaging secondary electron bremsstrahlung X-rays during irradiation of carbon-ions even near clinical conditions. | |||||
書誌情報 |
Physics Medicine Biology 巻 64, 号 13, p. 135019-1-135019-15, 発行日 2019-07 |
|||||
出版者 | ||||||
出版者 | IOP Publishing | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0031-9155 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1088/1361-6560/ab2072 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1088/1361-6560/ab2072 |