{"_buckets": {"deposit": "50d8122f-4b8d-41d7-940b-a7c47dece073"}, "_deposit": {"created_by": 1, "id": "75716", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "75716"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00075716", "sets": ["29"]}, "author_link": ["1019672", "1019673", "1019665", "1019670", "1019664", "1019667", "1019666", "1019675", "1019674", "1019676", "1019669", "1019668", "1019677", "1019671"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2019-04-11", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "[Purpose] We have proposed a new concept of whole gamma imaging (WGI), which is a novel combination of PET and Compton imaging, and we have showed by simulation the feasibility of triple-gamma imaging targeting β+-γ emitters, which emit both a positron and a gamma ray almost at the same time. In this study, we developed a proof-of-concept prototype of the WGI and an imaging method for the triple-gamma imaging incorporating resolution modeling.\n[Method] We developed a WGI prototype by inserting a scatterer detector ring (20 cm in inner diameter, 20x2 (transverse x axial) detectors each consisted of a 24x24x1 array of 0.9x0.9x6-mm3 GAGG crystals and a 8x8 array of 3-mm multipixel photon counters (MPPCs)) into a PET (absorber) detector ring (66 cm in inner diameter, 40x4 detectors each consisted of a 16x16x4 array of 2.8x2.8x7.5-mm3 Zr-doped GSO crystals and 64-ch photo multiplier tubes). In the triple-gamma imaging, radioactivity source position can be determined as the intersection point between a line-of-response (positron) and a Compton cone (gamma ray) in the field of view. The half-cone angle of the Compton cone is equal to the scatter angle determined by the Klein-Nishina equation using energy information. We derived an equation necessary to determine the intersection point and developed a method to model blurring effect of the cone due to the energy resolution of the detectors. To demonstrate the effectiveness of the triple-gamma imaging, we measured a 22Na point source, which emits a positron and a 1274 keV gamma ray, placed at various positions by using the WGI prototype.\n[Results] We compared triple-gamma images generated by back-projection using the proposed model and using only LOR information for the same list-mode data set. The proposed method could generate clearer image.\n[Conclusion] We demonstrated that the triple-gamma imaging is possible with the WGI prototype and the proposed method.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第117回日本医学物理学会学術大会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "田島, 英朗"}], "nameIdentifiers": [{"nameIdentifier": "1019664", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田, 英治"}], "nameIdentifiers": [{"nameIdentifier": "1019665", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "奥村, 勇介"}], "nameIdentifiers": [{"nameIdentifier": "1019666", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "菅, 幹生"}], "nameIdentifiers": [{"nameIdentifier": "1019667", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "河地, 有木"}], "nameIdentifiers": [{"nameIdentifier": "1019668", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kamada, Kei"}], "nameIdentifiers": [{"nameIdentifier": "1019669", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Parodi, Katia"}], "nameIdentifiers": [{"nameIdentifier": "1019670", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷, 泰賀"}], "nameIdentifiers": [{"nameIdentifier": "1019671", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hideaki, Tashima", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1019672", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Eiji, Yoshida", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1019673", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yusuke, Okumura", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1019674", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mikio, Suga", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1019675", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Naoki, Kawachi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1019676", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Taiga, Yamaya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1019677", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Whole Gamma Imaging: demonstration of the β+-γ coincidence", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Whole Gamma Imaging: demonstration of the β+-γ coincidence"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/75716", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-04-25"}, "publish_date": "2019-04-25", "publish_status": "0", "recid": "75716", "relation": {}, "relation_version_is_last": true, "title": ["Whole Gamma Imaging: demonstration of the β+-γ coincidence"], "weko_shared_id": -1}
Whole Gamma Imaging: demonstration of the β+-γ coincidence
https://repo.qst.go.jp/records/75716
https://repo.qst.go.jp/records/75716a9b384bc-b6b8-47f0-95e4-2ac73cb265cc
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-04-25 | |||||
タイトル | ||||||
タイトル | Whole Gamma Imaging: demonstration of the β+-γ coincidence | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
田島, 英朗
× 田島, 英朗× 吉田, 英治× 奥村, 勇介× 菅, 幹生× 河地, 有木× Kamada, Kei× Parodi, Katia× 山谷, 泰賀× Hideaki, Tashima× Eiji, Yoshida× Yusuke, Okumura× Mikio, Suga× Naoki, Kawachi× Taiga, Yamaya |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | [Purpose] We have proposed a new concept of whole gamma imaging (WGI), which is a novel combination of PET and Compton imaging, and we have showed by simulation the feasibility of triple-gamma imaging targeting β+-γ emitters, which emit both a positron and a gamma ray almost at the same time. In this study, we developed a proof-of-concept prototype of the WGI and an imaging method for the triple-gamma imaging incorporating resolution modeling. [Method] We developed a WGI prototype by inserting a scatterer detector ring (20 cm in inner diameter, 20x2 (transverse x axial) detectors each consisted of a 24x24x1 array of 0.9x0.9x6-mm3 GAGG crystals and a 8x8 array of 3-mm multipixel photon counters (MPPCs)) into a PET (absorber) detector ring (66 cm in inner diameter, 40x4 detectors each consisted of a 16x16x4 array of 2.8x2.8x7.5-mm3 Zr-doped GSO crystals and 64-ch photo multiplier tubes). In the triple-gamma imaging, radioactivity source position can be determined as the intersection point between a line-of-response (positron) and a Compton cone (gamma ray) in the field of view. The half-cone angle of the Compton cone is equal to the scatter angle determined by the Klein-Nishina equation using energy information. We derived an equation necessary to determine the intersection point and developed a method to model blurring effect of the cone due to the energy resolution of the detectors. To demonstrate the effectiveness of the triple-gamma imaging, we measured a 22Na point source, which emits a positron and a 1274 keV gamma ray, placed at various positions by using the WGI prototype. [Results] We compared triple-gamma images generated by back-projection using the proposed model and using only LOR information for the same list-mode data set. The proposed method could generate clearer image. [Conclusion] We demonstrated that the triple-gamma imaging is possible with the WGI prototype and the proposed method. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第117回日本医学物理学会学術大会 | |||||
発表年月日 | ||||||
日付 | 2019-04-11 | |||||
日付タイプ | Issued |