{"_buckets": {"deposit": "ea4cb0b8-93d6-44b9-a17c-f884e9850e2b"}, "_deposit": {"created_by": 1, "id": "74930", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "74930"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00074930", "sets": ["7"]}, "author_link": ["740395", "740398", "740402", "740403", "740397", "740396", "740401", "740399", "740400"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "7", "bibliographicPageEnd": "707", "bibliographicPageStart": "700", "bibliographicVolumeNumber": "74", "bibliographic_titles": [{"bibliographic_title": "日本放射線技術学会雑誌"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A survey on recognition, utilization, and evaluation for diagnostic reference levels (DRLs) after establishing Japan DRLs 2015 in the field of X-ray computed tomography (CT) was conducted for members of Japanese Society of Radiological Technology using web-based questionnaire system. The survey consisted of provincial branches to which respondents belong, their occupation, years of professional experience, years of experience in X-ray CT section, recognition of DRLs, and utilization and evaluation of DRLs in the field of X-ray CT section. Each survey item had one to eight questions. A total of 369 members completed the questionnaire. Among them, 295 out of 369 (79.9%) members knew that DRLs were released in Japan. After establishing the DRLs, 226 of 330 (68.5%) and 123 of 319 (38.6%) members investigated the doses used for adult and pediatric CT at their facilities, respectively. Although 345 of 369 (93.5%) members answered that DRLs are necessary for the field of X-ray CT, only 142 of 369 (38.5%) members thought that the established DRLs are enough to use in the field of X-ray CT. The survey has clarified the current status of recognition, utilization, and evaluation for DRLs in the field of X-ray CT after establishing the DRLs in Japan.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "松原孝祐"}], "nameIdentifiers": [{"nameIdentifier": "740395", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松永雄太"}], "nameIdentifiers": [{"nameIdentifier": "740396", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "梁川範幸"}], "nameIdentifiers": [{"nameIdentifier": "740397", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村松禎久"}], "nameIdentifiers": [{"nameIdentifier": "740398", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "井田義宏"}], "nameIdentifiers": [{"nameIdentifier": "740399", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木昇一"}], "nameIdentifiers": [{"nameIdentifier": "740400", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "赤羽, 恵一"}], "nameIdentifiers": [{"nameIdentifier": "740401", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石口恒男"}], "nameIdentifiers": [{"nameIdentifier": "740402", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akahane, Keiichi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "740403", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "X 線 CT 分野における診断参考レベルの 認知度,活用度,および評価に関する調査", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "X 線 CT 分野における診断参考レベルの 認知度,活用度,および評価に関する調査"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/74930", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-03-22"}, "publish_date": "2019-03-22", "publish_status": "0", "recid": "74930", "relation": {}, "relation_version_is_last": true, "title": ["X 線 CT 分野における診断参考レベルの 認知度,活用度,および評価に関する調査"], "weko_shared_id": -1}
X 線 CT 分野における診断参考レベルの 認知度,活用度,および評価に関する調査
https://repo.qst.go.jp/records/74930
https://repo.qst.go.jp/records/74930c8b72faf-5ca2-4247-9442-7f63bd3cb073
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-03-22 | |||||
タイトル | ||||||
タイトル | X 線 CT 分野における診断参考レベルの 認知度,活用度,および評価に関する調査 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
松原孝祐
× 松原孝祐× 松永雄太× 梁川範幸× 村松禎久× 井田義宏× 鈴木昇一× 赤羽, 恵一× 石口恒男× Akahane, Keiichi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A survey on recognition, utilization, and evaluation for diagnostic reference levels (DRLs) after establishing Japan DRLs 2015 in the field of X-ray computed tomography (CT) was conducted for members of Japanese Society of Radiological Technology using web-based questionnaire system. The survey consisted of provincial branches to which respondents belong, their occupation, years of professional experience, years of experience in X-ray CT section, recognition of DRLs, and utilization and evaluation of DRLs in the field of X-ray CT section. Each survey item had one to eight questions. A total of 369 members completed the questionnaire. Among them, 295 out of 369 (79.9%) members knew that DRLs were released in Japan. After establishing the DRLs, 226 of 330 (68.5%) and 123 of 319 (38.6%) members investigated the doses used for adult and pediatric CT at their facilities, respectively. Although 345 of 369 (93.5%) members answered that DRLs are necessary for the field of X-ray CT, only 142 of 369 (38.5%) members thought that the established DRLs are enough to use in the field of X-ray CT. The survey has clarified the current status of recognition, utilization, and evaluation for DRLs in the field of X-ray CT after establishing the DRLs in Japan. | |||||
書誌情報 |
日本放射線技術学会雑誌 巻 74, 号 7, p. 700-707, 発行日 2018-07 |