WEKO3
アイテム
{"_buckets": {"deposit": "a599f4c9-a631-4958-98fe-6317ed037995"}, "_deposit": {"created_by": 1, "id": "74831", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "74831"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00074831", "sets": ["2"]}, "author_link": ["739775", "739778", "739781", "739777", "739774", "739780", "739776", "739773", "739779"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-10", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "1197", "bibliographicPageStart": "1195", "bibliographic_titles": [{"bibliographic_title": "2018年第15回日本加速器学会年会プロシーディングス"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "At NIRS, re-acceleration of unstable 11C ion beam with the medical synchrotron, HIMAC has been pursuit in order to enable the real-time imaging of carbon ion irradiation into malignant tumor. Up to now 11C6+ ion beam has been tried with very limited intensities of ~10E5 per pulse created with a nuclear reaction of 12C6+ ion beams accelerated by HIMAC (so-called “Projectile Fragment Separation Scheme”) and it was not possible to attain good enough signal to noise ratio to obtain a diagnosable imaging. Recently the usage of 11C ion beam, produced by irradiation of a high intensity proton beam coming from a cyclotron has been investigated. For this purpose, we have studied the separation of the molecular 11CO2+ ion beam from the overwhelming 12CO2+ ion beam with the use of a double focusing magnet. The design of the double focusing magnet as well as the scheme to supply 11C4+ radioactive ions to HIMAC Injector to re-accelerate for cancer therapy is to be presented.", "subitem_description_type": "Abstract"}]}, "item_10003_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.pasj.jp/web_publish/pasj2018/proceedings/PDF/THP1/THP120.pdf", "subitem_relation_type_select": "URI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "野田, 章"}], "nameIdentifiers": [{"nameIdentifier": "739773", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Manfred, Grieser (MPIK)"}], "nameIdentifiers": [{"nameIdentifier": "739774", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原, 信幸"}], "nameIdentifiers": [{"nameIdentifier": "739775", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "片桐, 健"}], "nameIdentifiers": [{"nameIdentifier": "739776", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北條, 悟"}], "nameIdentifiers": [{"nameIdentifier": "739777", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "涌井, 崇志"}], "nameIdentifiers": [{"nameIdentifier": "739778", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白井, 敏之"}], "nameIdentifiers": [{"nameIdentifier": "739779", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田, 耕司"}], "nameIdentifiers": [{"nameIdentifier": "739780", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wakui, Takashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "739781", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "放射性11C+イオンビームの質量分離のための二重集束電磁石の設計", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "放射性11C+イオンビームの質量分離のための二重集束電磁石の設計"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/74831", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-03-20"}, "publish_date": "2019-03-20", "publish_status": "0", "recid": "74831", "relation": {}, "relation_version_is_last": true, "title": ["放射性11C+イオンビームの質量分離のための二重集束電磁石の設計"], "weko_shared_id": -1}
放射性11C+イオンビームの質量分離のための二重集束電磁石の設計
https://repo.qst.go.jp/records/74831
https://repo.qst.go.jp/records/74831693b4336-1756-4e78-8b6b-2f9e70efa500
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-03-20 | |||||
タイトル | ||||||
タイトル | 放射性11C+イオンビームの質量分離のための二重集束電磁石の設計 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
野田, 章
× 野田, 章× Manfred, Grieser (MPIK)× 宮原, 信幸× 片桐, 健× 北條, 悟× 涌井, 崇志× 白井, 敏之× 野田, 耕司× Wakui, Takashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | At NIRS, re-acceleration of unstable 11C ion beam with the medical synchrotron, HIMAC has been pursuit in order to enable the real-time imaging of carbon ion irradiation into malignant tumor. Up to now 11C6+ ion beam has been tried with very limited intensities of ~10E5 per pulse created with a nuclear reaction of 12C6+ ion beams accelerated by HIMAC (so-called “Projectile Fragment Separation Scheme”) and it was not possible to attain good enough signal to noise ratio to obtain a diagnosable imaging. Recently the usage of 11C ion beam, produced by irradiation of a high intensity proton beam coming from a cyclotron has been investigated. For this purpose, we have studied the separation of the molecular 11CO2+ ion beam from the overwhelming 12CO2+ ion beam with the use of a double focusing magnet. The design of the double focusing magnet as well as the scheme to supply 11C4+ radioactive ions to HIMAC Injector to re-accelerate for cancer therapy is to be presented. | |||||
書誌情報 |
2018年第15回日本加速器学会年会プロシーディングス p. 1195-1197, 発行日 2018-10 |
|||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.pasj.jp/web_publish/pasj2018/proceedings/PDF/THP1/THP120.pdf |