WEKO3
アイテム
{"_buckets": {"deposit": "978349e8-f435-4763-a256-4b9b4e1111b5"}, "_deposit": {"created_by": 1, "id": "74759", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "74759"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00074759", "sets": ["7"]}, "author_link": ["737520", "737523", "737521", "737522", "737519", "737524", "737525", "737526"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "93", "bibliographic_titles": [{"bibliographic_title": "QST Takasaki Annual Report 2017 "}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The cluster ion-specific irradiation effects have been observed in the analysis of ion-material interaction due to their unique feature such as very high-density energy deposition. The cluster ion beams may also cause a unique irradiation effects in biological samples, however, hardly applied so far. This study is aimed to establish an irradiation method of cluster ions for bacteria and investigate the cluster ion-specific effects by comparing the irradiation effects of cluster and monomer ion beams. In order to evaluate the accuracy of the measurement of beam current using a Faraday cup, we measured the particle fluence using a solid-state track detector. The results suggested that the measurement of beam current with the Faraday cup equipped in the TC line is accurate with the possible errors of 3~4% in both cluster and monomer ion beams.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "長谷, 純宏"}], "nameIdentifiers": [{"nameIdentifier": "737519", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤, 勝也"}], "nameIdentifiers": [{"nameIdentifier": "737520", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "千葉, 敦也"}], "nameIdentifiers": [{"nameIdentifier": "737521", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平野, 貴美"}], "nameIdentifiers": [{"nameIdentifier": "737522", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hase, Yoshihiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "737523", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sato, Katsuya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "737524", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Chiba, Atsuya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "737525", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hirano, Yoshimi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "737526", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Evaluation of Particle Fluence of Cluster and Monomer Ion Beams Using a Solid-state Track Detector", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Evaluation of Particle Fluence of Cluster and Monomer Ion Beams Using a Solid-state Track Detector"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/74759", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-03-15"}, "publish_date": "2019-03-15", "publish_status": "0", "recid": "74759", "relation": {}, "relation_version_is_last": true, "title": ["Evaluation of Particle Fluence of Cluster and Monomer Ion Beams Using a Solid-state Track Detector"], "weko_shared_id": -1}
Evaluation of Particle Fluence of Cluster and Monomer Ion Beams Using a Solid-state Track Detector
https://repo.qst.go.jp/records/74759
https://repo.qst.go.jp/records/747596f0bc60f-6144-4f98-9f61-7de793ebab91
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-03-15 | |||||
タイトル | ||||||
タイトル | Evaluation of Particle Fluence of Cluster and Monomer Ion Beams Using a Solid-state Track Detector | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
長谷, 純宏
× 長谷, 純宏× 佐藤, 勝也× 千葉, 敦也× 平野, 貴美× Hase, Yoshihiro× Sato, Katsuya× Chiba, Atsuya× Hirano, Yoshimi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The cluster ion-specific irradiation effects have been observed in the analysis of ion-material interaction due to their unique feature such as very high-density energy deposition. The cluster ion beams may also cause a unique irradiation effects in biological samples, however, hardly applied so far. This study is aimed to establish an irradiation method of cluster ions for bacteria and investigate the cluster ion-specific effects by comparing the irradiation effects of cluster and monomer ion beams. In order to evaluate the accuracy of the measurement of beam current using a Faraday cup, we measured the particle fluence using a solid-state track detector. The results suggested that the measurement of beam current with the Faraday cup equipped in the TC line is accurate with the possible errors of 3~4% in both cluster and monomer ion beams. | |||||
書誌情報 |
QST Takasaki Annual Report 2017 p. 93, 発行日 2019-03 |