WEKO3
アイテム
{"_buckets": {"deposit": "515db962-3f17-4ea1-b228-12ddc1383ee4"}, "_deposit": {"created_by": 1, "id": "72691", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "72691"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00072691", "sets": ["28"]}, "author_link": ["715983", "715986", "715988", "715992", "715991", "715984", "715987", "715995", "715997", "715990", "715994", "715980", "715989", "715993", "715982", "715981", "715996", "715985", "715979"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2018-03-27", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "【目的】炭素イオン線は特定の深さで線量が最大となるブラッグピーックを有し、腫瘍部分に効果を集中できるため、がん治療に最適である。しかし、ブラッグピーク手前の領域でも低い線エネルギー付与(LET, Linear Energy Transfer)の炭素イオン線に被ばくすることが知られている。従って、この領域の酸化還元(レドックス)状態を評価することは、正常組織に対する副作用を軽減する上で非常に重要である。本研究では、2,2-ジフェニル-1-ピクリルヒドラジル(DPPH)ラジカルをレドックスプローブとして用い、低LET炭素イオン線またはX線を照射した種々のDPPHラジカル溶液のレドックス状態を評価し、線質効果についても検討した。\n【実験】炭素イオン線(1〜20 Gy, 290 MeV/nucleon, 13.3 keV/µm)は放医研の重粒子がん治療装置HIMACにより照射した。X線(1〜20 Gy, 200 keV, 20 mA, 0.5 mm Cu + 0.5 mm Al, 1.79 Gy/min)の照射には島津Pantak HF-320を用いた。\n【結果および考察】β-シクロデキストリンを用いて水溶化したDPPHラジカル(Nakanishi I. et al, Chem. Commun. 51, 8311 (2015))の水溶液に炭素イオン線を照射すると、線量依存的にDPPHラジカルに由来する527 nmの吸収が減少した。527 nmの吸光度変化を線量に対してプロットすると直線が得られ、その傾き(-3.2 × 10(-3) Gy(-1))はX線を照射した場合(-3.8 × 10(-3) Gy(-1))とほぼ同じ値となった。メタノール中またはアセトニトリル中で同様の検討を行うと、この傾きは水の場合よりも大きくなったが、炭素イオン線とX線ではあまり変わらなかった。一方、ミリスチン酸イソプロピルを溶媒に用いた場合には、炭素イオン線の方がX線よりも方むかが顕著に大きくなり、飽和脂肪酸エステルはX線よりも炭素イオン線によって酸化されやすいことが示唆された。", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "日本薬学会第138年会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "中西, 郁夫"}], "nameIdentifiers": [{"nameIdentifier": "715979", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "東, 梨佳子"}], "nameIdentifiers": [{"nameIdentifier": "715980", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "下川, 卓志"}], "nameIdentifiers": [{"nameIdentifier": "715981", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山下, 真一"}], "nameIdentifiers": [{"nameIdentifier": "715982", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "関根(鈴木), 絵美子"}], "nameIdentifiers": [{"nameIdentifier": "715983", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上野, 恵美"}], "nameIdentifiers": [{"nameIdentifier": "715984", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川, 幸大"}], "nameIdentifiers": [{"nameIdentifier": "715985", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小澤, 俊彦"}], "nameIdentifiers": [{"nameIdentifier": "715986", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤崎, 真吾"}], "nameIdentifiers": [{"nameIdentifier": "715987", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 謙一郎"}], "nameIdentifiers": [{"nameIdentifier": "715988", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中西 郁夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "715989", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "東 梨佳子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "715990", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "下川 卓志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "715991", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山下 真一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "715992", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "関根 絵美子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "715993", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上野 恵美", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "715994", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川 幸大", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "715995", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小澤 俊彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "715996", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 謙一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "715997", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "炭素イオン線またはX線を照射した2,2-ジフェニル-1-ピクリルヒドラジルラジカル溶液のレドックス評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "炭素イオン線またはX線を照射した2,2-ジフェニル-1-ピクリルヒドラジルラジカル溶液のレドックス評価"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/72691", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-03-14"}, "publish_date": "2018-03-14", "publish_status": "0", "recid": "72691", "relation": {}, "relation_version_is_last": true, "title": ["炭素イオン線またはX線を照射した2,2-ジフェニル-1-ピクリルヒドラジルラジカル溶液のレドックス評価"], "weko_shared_id": -1}
炭素イオン線またはX線を照射した2,2-ジフェニル-1-ピクリルヒドラジルラジカル溶液のレドックス評価
https://repo.qst.go.jp/records/72691
https://repo.qst.go.jp/records/72691310f8bdf-ea16-4a7e-aa91-286e19efb6bc
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-03-14 | |||||
タイトル | ||||||
タイトル | 炭素イオン線またはX線を照射した2,2-ジフェニル-1-ピクリルヒドラジルラジカル溶液のレドックス評価 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
中西, 郁夫
× 中西, 郁夫× 東, 梨佳子× 下川, 卓志× 山下, 真一× 関根(鈴木), 絵美子× 上野, 恵美× 小川, 幸大× 小澤, 俊彦× 藤崎, 真吾× 松本, 謙一郎× 中西 郁夫× 東 梨佳子× 下川 卓志× 山下 真一× 関根 絵美子× 上野 恵美× 小川 幸大× 小澤 俊彦× 松本 謙一郎 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 【目的】炭素イオン線は特定の深さで線量が最大となるブラッグピーックを有し、腫瘍部分に効果を集中できるため、がん治療に最適である。しかし、ブラッグピーク手前の領域でも低い線エネルギー付与(LET, Linear Energy Transfer)の炭素イオン線に被ばくすることが知られている。従って、この領域の酸化還元(レドックス)状態を評価することは、正常組織に対する副作用を軽減する上で非常に重要である。本研究では、2,2-ジフェニル-1-ピクリルヒドラジル(DPPH)ラジカルをレドックスプローブとして用い、低LET炭素イオン線またはX線を照射した種々のDPPHラジカル溶液のレドックス状態を評価し、線質効果についても検討した。 【実験】炭素イオン線(1〜20 Gy, 290 MeV/nucleon, 13.3 keV/µm)は放医研の重粒子がん治療装置HIMACにより照射した。X線(1〜20 Gy, 200 keV, 20 mA, 0.5 mm Cu + 0.5 mm Al, 1.79 Gy/min)の照射には島津Pantak HF-320を用いた。 【結果および考察】β-シクロデキストリンを用いて水溶化したDPPHラジカル(Nakanishi I. et al, Chem. Commun. 51, 8311 (2015))の水溶液に炭素イオン線を照射すると、線量依存的にDPPHラジカルに由来する527 nmの吸収が減少した。527 nmの吸光度変化を線量に対してプロットすると直線が得られ、その傾き(-3.2 × 10(-3) Gy(-1))はX線を照射した場合(-3.8 × 10(-3) Gy(-1))とほぼ同じ値となった。メタノール中またはアセトニトリル中で同様の検討を行うと、この傾きは水の場合よりも大きくなったが、炭素イオン線とX線ではあまり変わらなかった。一方、ミリスチン酸イソプロピルを溶媒に用いた場合には、炭素イオン線の方がX線よりも方むかが顕著に大きくなり、飽和脂肪酸エステルはX線よりも炭素イオン線によって酸化されやすいことが示唆された。 |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 日本薬学会第138年会 | |||||
発表年月日 | ||||||
日付 | 2018-03-27 | |||||
日付タイプ | Issued |