WEKO3
アイテム
{"_buckets": {"deposit": "319339b9-69ad-4bb0-b3e6-56fa312e4d98"}, "_deposit": {"created_by": 1, "id": "71637", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "71637"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00071637", "sets": ["28"]}, "author_link": ["704867", "704869", "704873", "704874", "704880", "704866", "704877", "704876", "704872", "704879", "704878", "704870", "704868", "704865", "704871", "704875"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2015-04-21", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The goal of this experiment is veriflying the performance of new designed Tissue Equivalent Proportional Counter (TEPC) for monitoring space radiation. In space, cells could be exposed by complex radiation source, X-ray, Gamma ray, energetic electrons, protons and heavy charged particles in a huge range of energies. These generate much larger range of Linear Energy Transfer (LET) than ground and cause unexpected effect on human cells. In order to measure the large range of LET, from 0.2 to 1000 keV/μm, we developed a compact TEPC which measures ionized particles producedby collision between radiation sources and tissue equivalent (pure propane) gas in the detector . From measuring LET spectra, we can derive easily the equivalent dose from the complicated space radiation field. In this HIMAC experiment of 14H326, we calibrate and demonstrate the active radiation detector, TEPC with Fe 500 MeV/μ and C 290 MeV/ μ beams. In addition, we performed heavy ion experiments with the passive dosimeter, CR-39 in order to compare LET spectra measured by TEPC.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "平成26年度HIMAC共同利用研究成果発表会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nam, U."}], "nameIdentifiers": [{"nameIdentifier": "704865", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Lee, J."}], "nameIdentifiers": [{"nameIdentifier": "704866", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kim, S."}], "nameIdentifiers": [{"nameIdentifier": "704867", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Pyo, J."}], "nameIdentifiers": [{"nameIdentifier": "704868", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Moon, B."}], "nameIdentifiers": [{"nameIdentifier": "704869", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Park, W."}], "nameIdentifiers": [{"nameIdentifier": "704870", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uchihori, Y."}], "nameIdentifiers": [{"nameIdentifier": "704871", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitamura, H."}], "nameIdentifiers": [{"nameIdentifier": "704872", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kodaira, S."}], "nameIdentifiers": [{"nameIdentifier": "704873", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nam Ukwon", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "704874", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Lee Jaejin", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "704875", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kim Sunghwan", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "704876", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Pyo Jeonghyun", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "704877", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内堀 幸夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "704878", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北村 尚", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "704879", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小平 聡", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "704880", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Calibration of TEPC and personal dosimeter designed for ISS (International Space Station) dose measurement", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Calibration of TEPC and personal dosimeter designed for ISS (International Space Station) dose measurement"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/71637", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-04-23"}, "publish_date": "2015-04-23", "publish_status": "0", "recid": "71637", "relation": {}, "relation_version_is_last": true, "title": ["Calibration of TEPC and personal dosimeter designed for ISS (International Space Station) dose measurement"], "weko_shared_id": -1}
Calibration of TEPC and personal dosimeter designed for ISS (International Space Station) dose measurement
https://repo.qst.go.jp/records/71637
https://repo.qst.go.jp/records/71637fd33251c-ca62-489f-a717-c1a50551607c
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-04-23 | |||||
タイトル | ||||||
タイトル | Calibration of TEPC and personal dosimeter designed for ISS (International Space Station) dose measurement | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nam, U.
× Nam, U.× Lee, J.× Kim, S.× Pyo, J.× Moon, B.× Park, W.× Uchihori, Y.× Kitamura, H.× Kodaira, S.× Nam Ukwon× Lee Jaejin× Kim Sunghwan× Pyo Jeonghyun× 内堀 幸夫× 北村 尚× 小平 聡 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The goal of this experiment is veriflying the performance of new designed Tissue Equivalent Proportional Counter (TEPC) for monitoring space radiation. In space, cells could be exposed by complex radiation source, X-ray, Gamma ray, energetic electrons, protons and heavy charged particles in a huge range of energies. These generate much larger range of Linear Energy Transfer (LET) than ground and cause unexpected effect on human cells. In order to measure the large range of LET, from 0.2 to 1000 keV/μm, we developed a compact TEPC which measures ionized particles producedby collision between radiation sources and tissue equivalent (pure propane) gas in the detector . From measuring LET spectra, we can derive easily the equivalent dose from the complicated space radiation field. In this HIMAC experiment of 14H326, we calibrate and demonstrate the active radiation detector, TEPC with Fe 500 MeV/μ and C 290 MeV/ μ beams. In addition, we performed heavy ion experiments with the passive dosimeter, CR-39 in order to compare LET spectra measured by TEPC. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 平成26年度HIMAC共同利用研究成果発表会 | |||||
発表年月日 | ||||||
日付 | 2015-04-21 | |||||
日付タイプ | Issued |