WEKO3
アイテム
{"_buckets": {"deposit": "5e649dbc-21d7-4d00-9c13-c8b4964541b9"}, "_deposit": {"created_by": 1, "id": "70322", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "70322"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00070322", "sets": ["28"]}, "author_link": ["690549", "690540", "690545", "690544", "690552", "690550", "690535", "690551", "690538", "690553", "690541", "690542", "690537", "690539", "690543", "690554", "690547", "690548", "690536", "690546", "690555"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2010-11-06", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We previously reported on a new PET detector with 3 mm isotropic spatial resolution obtained using the X\u0027tal cube structure. The X\u0027tal cube is composed of a segmented crystal block and multi-pixel photon counters (MPPCs), and it detects scintillation photons in three dimensions (3D) by arranging MPPCs on multiple surfaces of the crystal block. With this structure and photo-detection method, we thought it would be possible to collect scintillation photons efficiently enough to get high spatial resolution.\n In this study, we achieved 1 mm isotropic spatial resolution. The developed X\u0027tal cube detector was composed of 96 MPPCs with 3.0 mm x 3.0 mm sensitive area and 1.0 x 1.0 x 1.0 mm3 LYSO crystals, which were structured into 16 x 16 x 16 arrays. We evaluated crystal identification and energy performance, and the results showed that the X\u0027tal cube has the expected 1 mm isotropic spatial resolution.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "2010 Nuclear Science Symposium and Medical Imaging Conference", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mitsuhashi, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "690535", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inadama, Naoko"}], "nameIdentifiers": [{"nameIdentifier": "690536", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishikido, Fumihiko"}], "nameIdentifiers": [{"nameIdentifier": "690537", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "690538", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murayama, Hideo"}], "nameIdentifiers": [{"nameIdentifier": "690539", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawai, Hideyuki"}], "nameIdentifiers": [{"nameIdentifier": "690540", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suga, Mikio"}], "nameIdentifiers": [{"nameIdentifier": "690541", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Haneishi, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "690542", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shibuya, Kengo"}], "nameIdentifiers": [{"nameIdentifier": "690543", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Watanabe, Mitsuo"}], "nameIdentifiers": [{"nameIdentifier": "690544", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "690545", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三橋 隆之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "690546", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲玉 直子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "690547", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "錦戸 文彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "690548", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 英治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "690549", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村山 秀雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "690550", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "河合 秀幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "690551", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "菅 幹生", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "690552", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "羽石 秀昭", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "690553", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "澁谷 憲悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "690554", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷 泰賀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "690555", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "1 mm Isotropic Detector Resolution Achieved by X\u0027tal Cube Detector", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "1 mm Isotropic Detector Resolution Achieved by X\u0027tal Cube Detector"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/70322", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-11-15"}, "publish_date": "2010-11-15", "publish_status": "0", "recid": "70322", "relation": {}, "relation_version_is_last": true, "title": ["1 mm Isotropic Detector Resolution Achieved by X\u0027tal Cube Detector"], "weko_shared_id": -1}
1 mm Isotropic Detector Resolution Achieved by X'tal Cube Detector
https://repo.qst.go.jp/records/70322
https://repo.qst.go.jp/records/70322fa20efb3-9f4a-4244-8248-5967062f2927
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-11-15 | |||||
タイトル | ||||||
タイトル | 1 mm Isotropic Detector Resolution Achieved by X'tal Cube Detector | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mitsuhashi, Takayuki
× Mitsuhashi, Takayuki× Inadama, Naoko× Nishikido, Fumihiko× Yoshida, Eiji× Murayama, Hideo× Kawai, Hideyuki× Suga, Mikio× Haneishi, Hideaki× Shibuya, Kengo× Watanabe, Mitsuo× Yamaya, Taiga× 三橋 隆之× 稲玉 直子× 錦戸 文彦× 吉田 英治× 村山 秀雄× 河合 秀幸× 菅 幹生× 羽石 秀昭× 澁谷 憲悟× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We previously reported on a new PET detector with 3 mm isotropic spatial resolution obtained using the X'tal cube structure. The X'tal cube is composed of a segmented crystal block and multi-pixel photon counters (MPPCs), and it detects scintillation photons in three dimensions (3D) by arranging MPPCs on multiple surfaces of the crystal block. With this structure and photo-detection method, we thought it would be possible to collect scintillation photons efficiently enough to get high spatial resolution. In this study, we achieved 1 mm isotropic spatial resolution. The developed X'tal cube detector was composed of 96 MPPCs with 3.0 mm x 3.0 mm sensitive area and 1.0 x 1.0 x 1.0 mm3 LYSO crystals, which were structured into 16 x 16 x 16 arrays. We evaluated crystal identification and energy performance, and the results showed that the X'tal cube has the expected 1 mm isotropic spatial resolution. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 2010 Nuclear Science Symposium and Medical Imaging Conference | |||||
発表年月日 | ||||||
日付 | 2010-11-06 | |||||
日付タイプ | Issued |