WEKO3
アイテム
{"_buckets": {"deposit": "1dd8792b-0598-4b72-bc07-29d31f02e8cc"}, "_deposit": {"created_by": 1, "id": "69568", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "69568"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00069568", "sets": ["28"]}, "author_link": ["682843", "682845", "682838", "682844", "682839", "682840", "682846", "682847", "682842", "682841"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2008-10-24", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "At nuclear emergency accident such as inhalation intake of alpha nuclide, an indispensable nasal swab method has not been used for precise internal dose estimation. One of the reasons is uncertainty in its radiation measurement, so that precise measurement with alpha spectrometry was examined for filter samples simulating nasal swab. It was confirmed that the alpha spectrometry made possible the distinction between solution and particulate in addition to the nuclide identification. The alpha activity in swab sample was precisely evaluated only when the detection efficiency was determined considering the self -absorption with filter fibers. Another big problem of wiping efficiency in nasal swabbing is still remain, but this study certainly raised the usefulness of the nasal swab method for rapid response in emergency.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "IRPA12", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Fukutsu, Kumiko"}], "nameIdentifiers": [{"nameIdentifier": "682838", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Yuji"}], "nameIdentifiers": [{"nameIdentifier": "682839", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kurihara, Osamu"}], "nameIdentifiers": [{"nameIdentifier": "682840", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Momose, Takumaro"}], "nameIdentifiers": [{"nameIdentifier": "682841", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miyabe, Kenjiro"}], "nameIdentifiers": [{"nameIdentifier": "682842", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akashi, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "682843", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福津 久美子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "682844", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 裕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "682845", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "栗原 治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "682846", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "明石 真言", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "682847", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Differences of detection efficiency among several nasal swab samples simulated for nuclear emergency accident", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Differences of detection efficiency among several nasal swab samples simulated for nuclear emergency accident"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/69568", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-11-11"}, "publish_date": "2008-11-11", "publish_status": "0", "recid": "69568", "relation": {}, "relation_version_is_last": true, "title": ["Differences of detection efficiency among several nasal swab samples simulated for nuclear emergency accident"], "weko_shared_id": -1}
Differences of detection efficiency among several nasal swab samples simulated for nuclear emergency accident
https://repo.qst.go.jp/records/69568
https://repo.qst.go.jp/records/695683c2b23b6-3139-4a51-b817-af4e3106196b
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-11-11 | |||||
タイトル | ||||||
タイトル | Differences of detection efficiency among several nasal swab samples simulated for nuclear emergency accident | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Fukutsu, Kumiko
× Fukutsu, Kumiko× Yamada, Yuji× Kurihara, Osamu× Momose, Takumaro× Miyabe, Kenjiro× Akashi, Makoto× 福津 久美子× 山田 裕司× 栗原 治× 明石 真言 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | At nuclear emergency accident such as inhalation intake of alpha nuclide, an indispensable nasal swab method has not been used for precise internal dose estimation. One of the reasons is uncertainty in its radiation measurement, so that precise measurement with alpha spectrometry was examined for filter samples simulating nasal swab. It was confirmed that the alpha spectrometry made possible the distinction between solution and particulate in addition to the nuclide identification. The alpha activity in swab sample was precisely evaluated only when the detection efficiency was determined considering the self -absorption with filter fibers. Another big problem of wiping efficiency in nasal swabbing is still remain, but this study certainly raised the usefulness of the nasal swab method for rapid response in emergency. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | IRPA12 | |||||
発表年月日 | ||||||
日付 | 2008-10-24 | |||||
日付タイプ | Issued |