WEKO3
アイテム
{"_buckets": {"deposit": "5e2190ca-a9b5-4d58-b430-efc037693006"}, "_deposit": {"created_by": 1, "id": "68223", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "68223"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00068223", "sets": ["28"]}, "author_link": ["669866", "669867"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2005-10-29", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We are developing a high-performance brain PET scanner, jPET-D4. This scanner is designed to achieve not only high spatial resolution but also high sensitivity using four-layered depth-of-interaction (DOI) detectors. The scanner has five detector rings with the ring diameter of 390 mm and each detector ring consists of 24 DOI detectors. In order to identify the crystal of interaction and its energy from PMT output, we have previously proposed the DOI detector calibration method. This method creates position and energy Look-Up-Tables (LUTs) from the uniform irradiation. The position LUT converts location of 2D position histograms to crystal addresses. The energy LUT corrects light output of each crystal. Five detector rings have been installed and calibrated. The average energy resolution for 120 DOI detectors is optimized to 17 %. The scatter fraction for this system is 38 % with energy window of 400-600 keV. The sensitivity for point source is 112 kcps/MBq with a 250 keV LLD.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "Medical Image Conference", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yoshida, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "669866", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 英治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "669867", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "The jPET-D4: Detector Calibration and Acquisition System of the 4-layer DOI-PET Scanner", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "The jPET-D4: Detector Calibration and Acquisition System of the 4-layer DOI-PET Scanner"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/68223", "pubdate": {"attribute_name": "公開日", "attribute_value": "2005-11-04"}, "publish_date": "2005-11-04", "publish_status": "0", "recid": "68223", "relation": {}, "relation_version_is_last": true, "title": ["The jPET-D4: Detector Calibration and Acquisition System of the 4-layer DOI-PET Scanner"], "weko_shared_id": -1}
The jPET-D4: Detector Calibration and Acquisition System of the 4-layer DOI-PET Scanner
https://repo.qst.go.jp/records/68223
https://repo.qst.go.jp/records/68223d54f9f84-6628-4bed-9e46-1f6650b6caf0
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-11-04 | |||||
タイトル | ||||||
タイトル | The jPET-D4: Detector Calibration and Acquisition System of the 4-layer DOI-PET Scanner | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yoshida, Eiji
× Yoshida, Eiji× 吉田 英治 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We are developing a high-performance brain PET scanner, jPET-D4. This scanner is designed to achieve not only high spatial resolution but also high sensitivity using four-layered depth-of-interaction (DOI) detectors. The scanner has five detector rings with the ring diameter of 390 mm and each detector ring consists of 24 DOI detectors. In order to identify the crystal of interaction and its energy from PMT output, we have previously proposed the DOI detector calibration method. This method creates position and energy Look-Up-Tables (LUTs) from the uniform irradiation. The position LUT converts location of 2D position histograms to crystal addresses. The energy LUT corrects light output of each crystal. Five detector rings have been installed and calibrated. The average energy resolution for 120 DOI detectors is optimized to 17 %. The scatter fraction for this system is 38 % with energy window of 400-600 keV. The sensitivity for point source is 112 kcps/MBq with a 250 keV LLD. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Medical Image Conference | |||||
発表年月日 | ||||||
日付 | 2005-10-29 | |||||
日付タイプ | Issued |