WEKO3
アイテム
{"_buckets": {"deposit": "cb2a5d3c-949a-4b1e-9dbf-856f0215e2dd"}, "_deposit": {"created_by": 1, "id": "68181", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "68181"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00068181", "sets": ["28"]}, "author_link": ["669425", "669424"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2005-10-01", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Optimization of a moderator assembly for cyclotron-based BNCT was performed through simulations by considering a cooling system for neutron-production target. The calculated results showed that the target cooling system does not affect significantly the depth dose distribution in a phantom, and the optimized moderator assembly can provide the depth dose distribution better than that in a presently-available reactor-based neutron fields. This study also showed that it is important to optimize the thickness and/or the configuration of the collimator for each patient, because the thickness of the collimator greatly influences the depth dose distribution and absorbed dose to normal organs.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "The 4th Japan-Korea Joint Meeting on Medical Physics and The 5th Asia-Oceania Congress of Medical Physics", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yonai, Shunsuke"}], "nameIdentifiers": [{"nameIdentifier": "669424", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "米内 俊祐", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "669425", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Optimization of Moderator Assembly for Cyclotron-Based BNCT Taking Account of Target Structure", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Optimization of Moderator Assembly for Cyclotron-Based BNCT Taking Account of Target Structure"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/68181", "pubdate": {"attribute_name": "公開日", "attribute_value": "2005-10-07"}, "publish_date": "2005-10-07", "publish_status": "0", "recid": "68181", "relation": {}, "relation_version_is_last": true, "title": ["Optimization of Moderator Assembly for Cyclotron-Based BNCT Taking Account of Target Structure"], "weko_shared_id": -1}
Optimization of Moderator Assembly for Cyclotron-Based BNCT Taking Account of Target Structure
https://repo.qst.go.jp/records/68181
https://repo.qst.go.jp/records/681816885d2aa-b2a9-4590-88f5-446042d24c5a
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-10-07 | |||||
タイトル | ||||||
タイトル | Optimization of Moderator Assembly for Cyclotron-Based BNCT Taking Account of Target Structure | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yonai, Shunsuke
× Yonai, Shunsuke× 米内 俊祐 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Optimization of a moderator assembly for cyclotron-based BNCT was performed through simulations by considering a cooling system for neutron-production target. The calculated results showed that the target cooling system does not affect significantly the depth dose distribution in a phantom, and the optimized moderator assembly can provide the depth dose distribution better than that in a presently-available reactor-based neutron fields. This study also showed that it is important to optimize the thickness and/or the configuration of the collimator for each patient, because the thickness of the collimator greatly influences the depth dose distribution and absorbed dose to normal organs. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The 4th Japan-Korea Joint Meeting on Medical Physics and The 5th Asia-Oceania Congress of Medical Physics | |||||
発表年月日 | ||||||
日付 | 2005-10-01 | |||||
日付タイプ | Issued |