量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
<Purpose> This study reports and evaluates treatment planning including organ motion uncertainties for three-dimensional conformal therapy of lung cancer with respiration gated carbon ion broad beams. The distal margins were added by radiological path length.
<Materials and Methods> During treatment a patient is irradiated while the respiration signal from monitor placed on patient skin is close to end expiration phase of free breathing. Planning CT scans are taken gated with the same signal. To the CTV delineated on planning CT slices, margins for uncertainties in tumor movements are added based on fluoroscopy examinations typically 10 mm in cranial and 5 mm in caudal direction. The range compensator (RC) is designed for PTV that includes these margins under the assumption that the lung including tumor moves in cranial-caudal (CC) direction sliding along the chest wall.
<Results> Dose distributions are calculated for different tumor locations. Within the model of lung motion, CTV dose coverage is observed although the irradiated lung volume increases in enhanced degree due to the low electron density of lung.
<Discussions> The uncertainties in tumor motion are determined from clinical experience in fluoroscopy observations prior to irradiations. In order to reduce motion margins further, more accurate tumor position monitor is required. The effect of chest wall movement remains for future study with 4-D CT.
会議概要(会議名, 開催地, 会期, 主催者等)
4th Shinji Takahashi Memorial International Workshop on 3D-CRT