WEKO3
アイテム
{"_buckets": {"deposit": "4d45eba5-778f-4bff-a91f-9c664fd1608c"}, "_deposit": {"created_by": 1, "id": "67731", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "67731"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00067731", "sets": ["28"]}, "author_link": ["665588", "665587"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2004-03-26", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Based on 10 years experience of carbon therapy at HIMAC, the conceptual design of the carbon therapy accelerator facility has been carried out in order to provide such beneficial treatment around Japan. It is required for the synchrotron to accelerate carbon ions from 4 MeV/u of injection energy to 400 MeV/u corresponding to the 275 mm range in water. In the design of the synchrotron, the radius of 10 m and the dipole-magnet filling factor of 43 % are achieved with FODO lattice structure. In this paper, the conceptual design of the synchrotron dedicated to carbon therapy is presented.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "The Asian Particle Accelerator Conference", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Furukawa, Takuji"}], "nameIdentifiers": [{"nameIdentifier": "665587", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 卓司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "665588", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "HIMAC and New Facility Design for Wide Spread Use of Carbon Cancer Therapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "HIMAC and New Facility Design for Wide Spread Use of Carbon Cancer Therapy"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/67731", "pubdate": {"attribute_name": "公開日", "attribute_value": "2004-03-29"}, "publish_date": "2004-03-29", "publish_status": "0", "recid": "67731", "relation": {}, "relation_version_is_last": true, "title": ["HIMAC and New Facility Design for Wide Spread Use of Carbon Cancer Therapy"], "weko_shared_id": -1}
HIMAC and New Facility Design for Wide Spread Use of Carbon Cancer Therapy
https://repo.qst.go.jp/records/67731
https://repo.qst.go.jp/records/67731e0c87d20-9ef5-43aa-a705-f9a867e89610
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2004-03-29 | |||||
タイトル | ||||||
タイトル | HIMAC and New Facility Design for Wide Spread Use of Carbon Cancer Therapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Furukawa, Takuji
× Furukawa, Takuji× 古川 卓司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Based on 10 years experience of carbon therapy at HIMAC, the conceptual design of the carbon therapy accelerator facility has been carried out in order to provide such beneficial treatment around Japan. It is required for the synchrotron to accelerate carbon ions from 4 MeV/u of injection energy to 400 MeV/u corresponding to the 275 mm range in water. In the design of the synchrotron, the radius of 10 m and the dipole-magnet filling factor of 43 % are achieved with FODO lattice structure. In this paper, the conceptual design of the synchrotron dedicated to carbon therapy is presented. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The Asian Particle Accelerator Conference | |||||
発表年月日 | ||||||
日付 | 2004-03-26 | |||||
日付タイプ | Issued |