WEKO3
アイテム
{"_buckets": {"deposit": "a39e4600-8de9-48be-9fc2-029510d6e59e"}, "_deposit": {"created_by": 1, "id": "66324", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "66324"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00066324", "sets": ["29"]}, "author_link": ["652596", "652598", "652603", "652600", "652597", "652599", "652593", "652602", "652595", "652589", "652594", "652592", "652588", "652587", "652590", "652601", "652591"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2017-04-13", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "[Purpose] We proposed an add-on PET system integrated with a birdcage RF-coil for PET/MRI system based on 4-layered depth-of-interaction (DOI) detectors. The PET detectors are placed close to a head to achieve both high sensitivity and high spatial resolution even at the edge of the field of view (FOV). We constructed a new RF-coil for a second prototype of add-on PET, which is combined with 24 DOI-PET detectors and evaluated performance.\n[Methods] The second prototype consisted of an RF-coil and 24 PET detector units with two PET detectors each. The detector units were shielded with carbon fiber shielding boxes. Each PET detector consisted of a 14 x 14 x 4-layer array of lutetium fine silicate (LFS) crystals (1.9 mm x 1.9 mm x 4.0 mm), an 8 x 8 multi-pixel photon counter (MPPC, S12641PA-050) array and a readout circuit board with an ASIC. The RF coil was dedicated to a 3T MRI (MAGNETOM Verio, Siemens). \nIn the evaluation, PET detector performances in simultaneous measurement and spatial resolutions of PET images were measured with a 22Na point-like source and a mini Derenzo phantom. Spin echo (SE) and echo planer imaging (EPI) techniques were used in the evaluation experiment of the simultaneous measurements. \n[Results] The influence of the simultaneous measurements with MRI on the PET performance was negligible. All of 1.6 mm hot rods were distinguished in the phantom ezperiment. \n[Conclusion] The influence of the simultaneous measurements with MRI on the PET performance was negligible. In addition, the superior spatial resolution of the PET images was obtained.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第113回医学物理学会学術大会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "錦戸, 文彦"}], "nameIdentifiers": [{"nameIdentifier": "652587", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤原, 理伯"}], "nameIdentifiers": [{"nameIdentifier": "652588", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岩男, 悠真"}], "nameIdentifiers": [{"nameIdentifier": "652589", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田島, 英朗"}], "nameIdentifiers": [{"nameIdentifier": "652590", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田, 英治"}], "nameIdentifiers": [{"nameIdentifier": "652591", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "菅, 幹生"}], "nameIdentifiers": [{"nameIdentifier": "652592", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "清水, 啓司"}], "nameIdentifiers": [{"nameIdentifier": "652593", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小畠, 隆行"}], "nameIdentifiers": [{"nameIdentifier": "652594", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷, 泰賀"}], "nameIdentifiers": [{"nameIdentifier": "652595", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "錦戸 文彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "652596", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤原 理伯", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "652597", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岩男 悠真", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "652598", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田島 英朗", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "652599", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田 英治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "652600", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "菅 幹生", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "652601", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小畠 隆行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "652602", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷 泰賀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "652603", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Development of second add-on PET/MRI prototype: Evaluation of PET imaging performance", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of second add-on PET/MRI prototype: Evaluation of PET imaging performance"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/66324", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-05-18"}, "publish_date": "2017-05-18", "publish_status": "0", "recid": "66324", "relation": {}, "relation_version_is_last": true, "title": ["Development of second add-on PET/MRI prototype: Evaluation of PET imaging performance"], "weko_shared_id": -1}
Development of second add-on PET/MRI prototype: Evaluation of PET imaging performance
https://repo.qst.go.jp/records/66324
https://repo.qst.go.jp/records/663241012aa39-b377-4f70-980c-4f4542521092
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-05-18 | |||||
タイトル | ||||||
タイトル | Development of second add-on PET/MRI prototype: Evaluation of PET imaging performance | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
錦戸, 文彦
× 錦戸, 文彦× 藤原, 理伯× 岩男, 悠真× 田島, 英朗× 吉田, 英治× 菅, 幹生× 清水, 啓司× 小畠, 隆行× 山谷, 泰賀× 錦戸 文彦× 藤原 理伯× 岩男 悠真× 田島 英朗× 吉田 英治× 菅 幹生× 小畠 隆行× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | [Purpose] We proposed an add-on PET system integrated with a birdcage RF-coil for PET/MRI system based on 4-layered depth-of-interaction (DOI) detectors. The PET detectors are placed close to a head to achieve both high sensitivity and high spatial resolution even at the edge of the field of view (FOV). We constructed a new RF-coil for a second prototype of add-on PET, which is combined with 24 DOI-PET detectors and evaluated performance. [Methods] The second prototype consisted of an RF-coil and 24 PET detector units with two PET detectors each. The detector units were shielded with carbon fiber shielding boxes. Each PET detector consisted of a 14 x 14 x 4-layer array of lutetium fine silicate (LFS) crystals (1.9 mm x 1.9 mm x 4.0 mm), an 8 x 8 multi-pixel photon counter (MPPC, S12641PA-050) array and a readout circuit board with an ASIC. The RF coil was dedicated to a 3T MRI (MAGNETOM Verio, Siemens). In the evaluation, PET detector performances in simultaneous measurement and spatial resolutions of PET images were measured with a 22Na point-like source and a mini Derenzo phantom. Spin echo (SE) and echo planer imaging (EPI) techniques were used in the evaluation experiment of the simultaneous measurements. [Results] The influence of the simultaneous measurements with MRI on the PET performance was negligible. All of 1.6 mm hot rods were distinguished in the phantom ezperiment. [Conclusion] The influence of the simultaneous measurements with MRI on the PET performance was negligible. In addition, the superior spatial resolution of the PET images was obtained. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第113回医学物理学会学術大会 | |||||
発表年月日 | ||||||
日付 | 2017-04-13 | |||||
日付タイプ | Issued |