量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum and Radiological Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
Pulse duration of the ITER-relevant high power density hydrogen negative ion beams at 1 MeV has been successfully extended from 0.4 s to 60 s by using a prototype Multi-Aperture and Multi-Grid accelerator for the ITER and JT-60SA neutral beam systems. This significant progress was achieved based on developments of technology for the design of a voltage holding capability and improvement of a beam optics, which are directly applicable to ITER and JT-60SA. In the design of the voltage holding capability, one of critical remaining issues was a multi-grid effect. This was experimentally investigated by using a multi-grid configuration. This result was also applied to improve the beam optics by tuning the acceleration gap. In addition, the extractor configuration was optimized. These tunings significantly contributed to reduce the grid power load and to increase the current density. As the result, 0.97 MeV, 190 A/m2 negative ion beams were generated stably without any breakdowns and any thermal damages on the acceleration grids. This pulse length of the beams with the ITER-relevant energy and current density is the longest one in the world and contributes to assure the 1 MeV accelerator for the ITER NB system.